18
Measured Fill Calibration
Measured Fill Calibration
This allows you to fine-tune the amount of water dispensed from the preselected volumes.
The calibration mode is worked out as a percentage.
Assessing whether Measured Fill is accurate:
Press the
button until 1 L (1 qt) is displayed.
Dispense into a jug.
Estimate the amount of water dispensed.
To calculate the Calibration factor:
Transfer the difference into a percentage.
eg. 1000/975 = 1.03 = 103% or 32/31 = 1.03 = 103%
Enter the Calibration mode by pressing and holding the
and buttons together for 4
seconds.
The number displayed is a percentage. Adjust this accordingly using the and buttons.
eg. 100CAL = 103CAL
Press the
button to confirm your selection.
Please
note:
The Measured Fill function has an accuracy of +/-5% at the time of calibration.