517804 D
23
4.3
Icemaker Fault Codes
If a fault should develop with the Ice Making system, a LED will illuminate on the ice making PCB, which is
attached to the power module. The LED is visible from the back of the product; hence the product must be
wheeled away from the wall to view the fault codes. The number of LED flashes represents the fault code with
the icemaker itself.
Code Fault
0 (No LEDs)
No fault
1 Motor
timeout
2
Motor Current High – motor obstructed
3
Temperature sensor too hot
4
Temperature sensor too cold (or open circuit)
5
Water solenoid – current high
4.4
Icemaker Display Faults
If a fault has occurred relating to the display board, the fault code will show on the display just like any other
fault. The fault history is a tool to view intermittent faults.
Note: There will be no alarm/beeping if these faults occur.
Code Fault
F30
No display signal received (Shorted or Broken wire)
F31
No display signal received (shorted or broken wire) clock or data line.
Additional Fault Codes
F32
Solenoid Driver 1&2 (transistor) has failed. Or the solenoid has failed
F33
Solenoid Driver 2 (transistor has failed
F34
Both Solenoid Drivers have failed
Additional fault codes have been added to the display module in order to detect water leaks or continual flow
of water from the dispenser should a fault appear. Previous to these changes the software only counted water
flow when the solenoid was on. The new version of software (V1.067) now counts water flow when the water
valve is on or off.
Fault Code 32, 33 and 34 initial detection.
The first time this fault is detected there are two possible scenarios of how the customer/user will see it
happen.
Possibility 1
1. Dispense water
2. Remove glass/cup
3. Water continues to dispense for 5 seconds
4. Fault is detected
5. Water stops
6. After a certain period of time the display will show the customer/user what the fault code is.
Possibility 2
1. Dispense water
2. Remove glass/cup
3. Water stops
4. Fault is detected 5 seconds after the cup is removed
5. Water stops
6. After a period of time the display will show the user what the fault code is.
If both solenoid drivers fail and/or the water valve fails.
1. Dispense water
2. Remove glass/cup
3. Water continues to dispense until water supply is turned off.
4. Fault is detected
5. After a period of time the display will show what the fault code is.