517804 D
24
4.5
Testing Icemaker Sensor
The icemaker sensor is located on the bottom of the ice cube tray. The testing is carried out at the power
module.
Icemaker sensor located under
insulated pad
Sensor Insulator
•
Disconnect the refrigerator from the power supply.
•
Remove the power module from the product.
•
Remove the 11-pin RAST connector from the icemaker PCB.
•
The two white wires (Between Pin 10 & Pin 11) at the end of the RAST connectors are the sensor wires.
•
Testing of the sensor should be in a known stable temperature, such as a glass of water full of ice cubes.
4.6
Icemaker Sensor Resistance Table
Temperature
°
C
°
F
Resistance
(K
Ω
±
5%)
-30.0 -22
25.17
-25.0 -13
19.43
-20.0 -4
15.13
-15.0 5
11.88
-10.0 14
9.392
-5.0 23
7.481
0.0 32
6.000
5.0 41
4.844
10.0 50
3.935
15.0 59
3.217
20.0 68
2.644
25.0 77
2.186
30.0 86
1.817
35.0 95
1.518
40.0 104
1.274
45.0 113
1.075
50.0 122
0.9106