517804 D
31
6.9
To disable the filter Alarm - Products before January 2009)
Disable the alarm if no filter is to be fitted.
Press and hold the MEASURED FILL button, and press and hold the MENU and UP buttons for 4 seconds to
turn this feature on/off.
6.10
Flowmeter Calibration/ Measured Fill Calibration - (Products
before January 2009)
This calibration is to be carried out when the set quantities may be under or over the default settings.
Example: Default setting is 250 mls/8fl ozs, however only 200 mls/7fl ozs is being dispensed.
Press and hold the MEASURED FILL button, then press the DOWN button to enter the calibration mode.
100 CAL will be displayed in the MEASURED FILL window.
The 100 display is a percentage. It can be increased by using the UP button, or decreased by using the
DOWN button.
6.11
To disable Filter Alarm (Products after January 2009)
Disable the alarm if no filter is to be fitted.
Press and hold the
MENU
+
UP
+
LOCK
buttons for 4 seconds to turn this feature on/off.
6.12 Noises
Ice and water into the Active Smart products introduced some unfamiliar sounds, which are normal. The
noises are difficult to hear and may not be heard during the day but during the night may sound louder.
Cracking Noise
The ice cracking is due to the ice tray being twisted to loosen the ice cubes in the ice tray.
Humming.
There will be a low humming noise when the ice tray motor/gearbox rotates the tray to flip the ice cubes from
the tray.
Clunking Noise.
Ice falling into the ice bin may initially make a noise then disappear. The reason for this is that there is no ice in
the bin but as the bin fills with ice the noise lessens.
Water Filling
After the ice trays bins empties and returns to its normal position the water valve comes on to refill the tray, the
noise will be a hissing or water running noise. How often this noise appears will be dependent on time the
water takes to reach freezing temperature.