background image

Summary of Contents for HC60PLX4

Page 1: ...Chimney Pyramid Rangehood HC60PLX4 and HC90PLX4 models NZ AU INSTALLATION INSTRUCTIONS USER GUIDE ...

Page 2: ......

Page 3: ...is user guide may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please go to our website www fisherpaykel com or contact your local Fisher Paykel dealer Registration Register your product with us so we can provide you with the best service possible To register your product visit our website www f...

Page 4: ......

Page 5: ...wer supply only by a suitably qualified person according to these installation instructions and in compliance with any applicable local building and electricity regulations Failure to install the appliance correctly could invalidate any warranty or liability claims To comply with electrical safety regulations the rangehood must be plugged into a socket near the appliance The socket must be accessi...

Page 6: ...n responsible for their safety Children should be supervised to ensure they do not play with the appliance Cleaning and user maintenance shall not be made by children without supervision You must read the details concerning the method and frequency of cleaning There is a fire risk if cleaning is not carried out in accordance with the instructions Never leave frying food unattended since grease can...

Page 7: ...guide manual 1 Chimney 1 125 mm diameter ducting adapter 1 Expansion plug 8 Upper chimney 1 Rangehood 1 150 mm diameter ducting adapter 1 Chimney bracket 1 30 mm self tapping screw 4 10 mm self tapping screw 4 Chimney Pyramid Rangehood HC60PLX4 and HC90PLX4 models NZ AU INSTALLATION INSTRUCTIONS USER GUIDE ...

Page 8: ...chimney 290 290 G Distance from centre of ducting outlet to back of product 80 80 H Distance from centre of ducting outlet to side of chimney 160 160 I Diameter of ducting outlet 150 150 J Distance between centre of lights 235 370 K Distance between centre of lights to back of product 50 50 Length of power cord 1400 1400 IMPORTANT Actual product dimensions may vary by 2 mm Please read the entire i...

Page 9: ...cooktop to base of product Electric cooktop Gas cooktop min 600 max 750 min 650 max 750 L M Rangehood installation height above the cooktop is the user s preference Lower installation heights will improve the efficiency of capturing cooking odours grease and smoke This rangehood must be installed between the minimum and maximum dimensions indicated in the table above ...

Page 10: ... efficiency use the shortest and straightest duct route possible and use rigid or semi rigid ducting for reduced noise and increased airflow Flexible metal ducting should only be used as a last resort ie in difficult installations and if used ensure that it is straight and smooth and extended as much as possible Recirculating To enable the product to operate with the air recirculating please purch...

Page 11: ...grazed or knocked by tools Please take care to protect the surfaces during installation Protect the cooktop surface with cardboard or the like to prevent damage occurring whilst the rangehood is being installed above Temporarily mark the height of the bottom of the rangehood and the centre of the cooktop on the wall according to the information given in the Installation instructions Height of rang...

Page 12: ...ment point height 295 295 r Chimney bracket attachment point width 235 235 s Chimney bracket attachment point height 575 575 t Upper chimney bracket attachment point width 250 250 u Upper chimney bracket attachment point height 25 25 Fig 2 Upper chimney bracket attachment points Chimney bracket attachment points Upper rangehood attachment point Lower rangehood attachment point u s q O P r T N INST...

Page 13: ...11 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Fig 3 3 Attach the ducting adapter to the rangehood Place the ducting adapter onto the rangehood and screw it in place using the 10 mm screws ...

Page 14: ...r downwards until it disengages from the supports Hang the rangehood off the upper rangehood mounting screws with 2 mm gap Hang off the keyhole attachment points on the back of the rangehood then tighten the screws Attach the lower rangehood mounting screws to fix the rangehood to the wall Refit the filters ...

Page 15: ...inium duct tape and vent outside 6 Attach chimney Bend the tabs on the chimney A Place chimney around the hood chassis and hang off the bracket B Extend the upper chimney and attach to the chimney bracket with 10 mm screws C A B C 7 Remove packaging Remove all packaging and protective wrappings ...

Page 16: ...IONS Control panel Note we recommend turning your rangehood on before you start cooking for optimal performance Extractor fan operating control pilot light Lighting on and off Extractor fan off Extractor fan speed 1 2 and 3 ...

Page 17: ...rrosive which can cause damage to your rangehood Note in areas of high humidity or coastal environments cleaning should be carried out more frequently Aluminium filters Depending on use and at least once a month the aluminium grease filters should be removed and cleaned with hot soapy water or in a dishwasher If washed in a dishwasher the filters should be placed in an upright position to prevent ...

Page 18: ... from cooking vapours before the air is channelled back into the kitchen The active carbon filters must be replaced periodically to work properly at least every three months depending on the frequency with which the rangehood is used Note fully saturated carbon filters can become a barrier to air movement therefore limiting rangehood performance In the event of fire grease laden filters could be f...

Page 19: ...17 PARTS AND ACCESSORIES ITEM REFERENCE NUMBER bulb Aluminium filter 792527 Recirculation carbon filter x2 792481 Recirculation diverter 791820 PD RHK150E PD RHK150W ...

Page 20: ...r or our Customer Care Centre can recommend a Fisher Paykel Authorised Repairer in your area In Australia if you need assistance all the Fisher Paykel Customer Care Centre Toll Free 1300 650 590 Website www fisherpaykel com Postal address Fisher Paykel Appliances Ltd PO Box 798 Cleveland QLD 4163 If you need service Fisher Paykel has a network of Fisher Paykel trained and supported service technic...

Page 21: ...CUSTOMER CARE Complete and keep for safe reference Model Serial No Purchase Date Purchaser Dealer Suburb Town Country 19 ...

Page 22: ......

Page 23: ......

Page 24: ...nge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time For current details about model and specification availability in your country please go to our website or contact your local Fisher Paykel dealer ...

Reviews: