background image

Installation

1.

Preparing for installation:

Before installing your rangehood:

• Please read the instructions carefully.

• Unpack the rangehood and check that all functions are working.

• Ensure that the voltage (V) and the frequency (Hz) indicated on the serial plate match the voltage and frequency

at the installation site.

• Check that the area behind the installation surface to be drilled is clear of any electrical cables or pipes, etc.

• The stainless steel and glass surfaces of the rangehood are very easily damaged during installation if grazed or

knocked by tools. Please take care to protect the surfaces during installation.

• Protect the cooktop surface below with cardboard, or the like, to prevent damage occurring whilst the rangehood

is being installed above.

• Temporarily mark the height of the bottom of the rangehood and the centre of the cooktop on the wall according

to the information given in the ‘Installation instructions

◦ Height of rangehood’ section.

• The wall used for mounting the rangehood should have sufficient strength and a flat surface.

2.

Attach chimney brackets and hood mounting
screws

• Attach the chimney bracket and upper chimney

bracket (if using the upper chimney) in the
locations shown in Fig.2 and 3. Use the 30 mm
screws and expansion plugs if attaching to
masonry.

• Attach the upper hood mounting screws in the

locations shown in Fig.2 and 3. Use the 30 mm
screws and expansion plugs if attaching to
masonry. Ensure that there is a 2 mm gap
between the screw head and the wall – see
Fig.1.

Fig. 1

https://producthelp.fisherpaykel.com/au/Cook/Rangehoods/Canopy/HC90DCXB3/User_Guide_HC90DCXB3/03_Installation_instructions

Updated: Wed, 06 Mar 2019 11:36:04 GMT

Powered by

8

Summary of Contents for HC90DCXB3

Page 1: ...ections carefully before using your rangehood Contents of packaging Rangehood 1 Installation instructions User guide manual 1 Chimney 1 https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated Wed 06 Mar 2019 11 36 04 GMT Powered by 1 ...

Page 2: ...ing adapter 1 Expansion plug 8 30 mm self tapping screw 8 10 mm self tapping screw 4 125 mm ducting adapter 1 https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated Wed 06 Mar 2019 11 36 04 GMT Powered by 2 ...

Page 3: ...https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated Wed 06 Mar 2019 11 36 04 GMT Powered by 3 ...

Page 4: ...290 H Distance from centre of ducting outlet to back of product 82 82 82 I Distance from centre of ducting outlet to side of chimney 160 160 160 J Diameter of ducting outlet 150 150 150 K Distance between centre of lights 230 230 230 L Distance from centre of lights to back of product 45 45 45 Length of power cord 1200 1200 1200 https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB...

Page 5: ...Ducted externally Recirculation mode min 635 max 1035 min 675 max 1035 N Height top of cooktop to base of product Electric cooktop for induction cooktop see note below Gas cooktop min 600 max 750 min 650 max 750 https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated Wed 06 Mar 2019 11 36 04 GMT Powered by 5 ...

Page 6: ...ce condensation For example aggressive boiling on high cooktop heat settings like PowerBoost increases the rate at which water is evaporated increasing the likelihood of condensation It is important to understand that neither the rangehood nor the induction cooktop are faulty as a result of this phenomenon Condensation can be minimised by Installing the rangehood at the maximum height above the co...

Page 7: ...kitchen please purchase a recirculation diverter and carbon filters refer to the Parts and accessories section The recirculation diverter is installed after a short length of ducting and is required to channel the air out the side vents at the top of the chimney and the carbon filters are required to remove odours A ducting hole is not required in the wall or ceiling if the rangehood is installed ...

Page 8: ...installed above Temporarily mark the height of the bottom of the rangehood and the centre of the cooktop on the wall according to the information given in the Installation instructions Height of rangehood section The wall used for mounting the rangehood should have sufficient strength and a flat surface 2 Attach chimney brackets and hood mounting screws Attach the chimney bracket and upper chimney...

Page 9: ...cket attachment point height 559 559 556 C Upper rangehood attachment point height 286 286 288 D Lower rangehood attachment point height 36 36 42 5 https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated Wed 06 Mar 2019 11 36 04 GMT Powered by 9 ...

Page 10: ...using the 10 mm screws 4 Attach hood to wall Remove filters and air flow balancing plate from hood as shown in Fig 4 https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated Wed 06 Mar 2019 11 36 04 GMT Powered by 10 ...

Page 11: ...rs 5 Attach ducting Attach ducting to ducting adapter using aluminium duct tape 6 Attach chimney Bend the tabs on the chimney A Place chimney around the hood chassis and hang off the bracket B Extend the upper chimney and attach to the chimney bracket with 10 mm screws C https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated...

Page 12: ...A B C https producthelp fisherpaykel com au Cook Rangehoods Canopy HC90DCXB3 User_Guide_HC90DCXB3 03_Installation_instructions Updated Wed 06 Mar 2019 11 36 04 GMT Powered by 12 ...

Reviews: