 INSTALLATION PREPARATION

IMPORTANT

Rangehood width

The smaller rangehood models are only intended to be installed over a cooktop with a 
maximum of four burners or cooking zones.

The rangehood width is recommended to be no less than the width of the cooktop.

A wider rangehood can be used to increase the capture area if space is not restricted.

The rangehood should ideally be centred above the cooktop for proper performance.

Installation location — Ducting preparation

The rangehood is suspended under the cabinetry. The ducting can be configured for 
both vertical and horizontal discharge. The ducting can terminate either through the roof 
or wall, to vent through the wall a 90° elbow is needed.

Optional extras

All optional extras must be installed prior to the rangehood being installed.

Remote control

If an optional remote control was purchased for installation with the rangehood the 
remote control receiver must be assembled into the rangehood prior to installation. 
Installation must be undertaken by an approved service technician. Instructions for 
installation are provided with the receiver.

Duct adaptor

A 250mm round duct adaptor is supplied with the HB9048-2 & HPB12048-2 models to 
mount to the top of the rangehood to provide a single outlet. This should be installed before 
the rangehood is mounted.

Duct adaptor assembly

Place the duct adaptor over the rangehood exhaust and secure with four 8mm screws 
provided (refer to 

A

).

Seal the connection between duct adaptor and rangehood with aluminium tape (refer to 

B

).

Rangehood height

INSTALLATION DIMENSIONS

mm

A

Top of cooking surface to base of 
the rangehood 

Minimum 600 

Maximum recommended 1067

The installation height ranges from a minimum height 
of 600mm to a maximum recommended height of 
1067mm. Consult the cooktop Installation and User 
guide for details of the required installation height of 
the rangehood.

This rangehood must be installed no lower than the 
minimum height indicated in the table above. Minimum 
installation height may be greater if required by the 
cooktop manufacturer. Installation at the minimum 
height will improve the efficiency of capturing cooking 
odors, grease and smoke. Installation at the maximum 
recommended height improves user ergonomics by 
offering increased head room.

IMPORTANT

Always switch your rangehood on when you are 

cooking.

Using a powerful gas cooktop or multiple gas burners 

operating at the same time can cause the rangehood 

surfaces to become hot, this effect can be reduced by:

–   Using the maximum speed setting to enable hot 

air to be extracted quickly.

–   Installing the rangehood at the maximum 

recommended height. Consult the cooktop 

Installation and User guide for details on the 

installation height of the rangehood.

Cabinet mounting installation

The cabinet must be of sufficient strength and structurally 
joined to the wall studs to support the weight of this 
rangehood.

If support beams are added to cabinetry these must not 
be more than 38mm 

B

 high from the underside of the 

cabinet. Beams that are higher will prevent access for 
servicing. 

The rangehood must be installed into an opening on the 
underside of the cabinet.

Cabinet opening dimensions that are shown must be 
used, see ‘Product and cabinetry cut-out dimensions’ 
section. Given dimensions provide minimum clearance.

We recommend the cupboard has a door or service panel 
that can be easily opened to access the power connection.

A

B

A

B

Summary of Contents for HPB12048-2

Page 1: ...INTEGRATED RANGEHOOD HPB6028 1 HPB7528 1 HPB7548 1 HPB9028 1 HPB9048 1 HPB9048 2 HPB12048 2 models INSTALLATION GUIDE NZ AU ROW 105464A 02 19 ...

Page 2: ......

Page 3: ...e that any applicable regulations concerning the discharge of exhaust air are fulfilled Exhaust air must not be discharged into an existing flue that is used for exhausting fumes from appliances burning gas or other fuels 2 PRODUCT INFORMATION IMPORTANT SAVE THIS GUIDE The models shown in this installation guide may not be available in all markets and are subject to change at any time For current ...

Page 4: ...CABINETRY CUT OUT DIMENSIONS HPB6028 1 HPB7528 1 HPB7548 1 HPB9028 1 HPB9048 1 HPB9048 2 and HPB12048 2 models Refer to page 4 for details on Cabinet mounting installation 38mm C C D D L M G K N J H I O Q B A E P F S R ...

Page 5: ...2 J Height of side of chassis 111 111 111 111 111 111 111 K Width of blower housing 330 330 330 330 330 590 590 l Offset of duct adaptor forward of centre 23 23 23 23 23 0 0 m Outside diameter of ducting outlet 150 150 150 150 150 250 250 n Width of duct adaptor N A N A N A N A N A 310 310 o Depth of duct adaptor N A N A N A N A N A 318 318 p Distance from centre of light to front of product 35 5 ...

Page 6: ... of the rangehood Minimum 600 Maximum recommended 1067 The installation height ranges from a minimum height of 600mm to a maximum recommended height of 1067mm Consult the cooktop Installation and User guide for details of the required installation height of the rangehood This rangehood must be installed no lower than the minimum height indicated in the table above Minimum installation height may b...

Page 7: ...or if doubt exists as to whether the appliance is properly earthed grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance WARNING Improper earthing grounding can result in a risk of electric shock Venting requirements IMPORTANT To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not...

Page 8: ... should have sufficient strength and a flat surface 1 Ensure the cabinetry has the required cutout for insertion of the rangehood Refer to the Cabinetry cutout dimensions section of this installation book 2 If you are using a duct adaptor this must be installed to the rangehood prior to the rangehood being mounted Please refer to Duct adaptor assembly for details on how to install your duct adapto...

Page 9: ...7 5 INSTALLATION INSTRUCTIONS Note The rangehood must be installed with the control panel on the right D C E F ...

Page 10: ......

Page 11: ......

Page 12: ...cations in this document apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this document correctly describes the product currently available ...

Reviews: