background image

Important!    

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, 
please go to our local website listed at the end of this document or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

 

Important safety instructions! 

 

To avoid hazard, read and follow these instructions carefully before installing or

 

using this appliance.

 

Please make this information available to the person installing the appliance, as it

 

could reduce your installation costs.

 

This appliance is to be installed and connected to the electricity supply only by a

 

qualified electrician.

 

Installation must comply with your local building and electricity regulations.

 

Failure to install the appliance correctly could invalidate any warranty or liability

 

claims.

 

This appliance is designed for permanent fixture and has to be connected to the

 

mains electricity supply.

 

The appliance must not be installed above cookers with eye-level grills.

 

The appliance is heavy, take care when lifting or handling.

 
 

 

WARNING!

   

   Cut 

Hazard

 

Take care - panel edges are sharp.

 

Failure to use caution could result in injury or cuts.

 

WARNING!

   

 

 

Electrical shock hazard

 

Always disconnect the appliance from the mains electricity supply before    

 

carrying out any servicing or maintenance operations.

 

Failure to do so could result in electrical shock or death.

 

Before you install the appliance, please make sure that

 

 

the voltage (V) and frequency (Hz) indicated on the serial number plate as well as

 

the specifications on the rating plate on the inside of the appliance correspond to

 

the voltage and frequency of the mains supply.

 

the room in which the appliance is installed is well-ventilated.

 

the wall is able to withstand the total weight (34 kg) of the appliance mounted on it.

 

if the air is to be ducted, the flue is in good condition, especially if it has been out of

 

use for a long period of time.

 

If the air is to be ducted, it will not be discharged into a flue that is used for

 

exhausting fumes from appliances burning gas or other fuels.

 

the installation will comply with laws and regulations regarding ducting waste

 

gases.

 

for optimal efficiency, use smooth ducting for reduced noise and increased airflow. Flexible ducting 
should only be used as a last resort.

 

When you install the appliance, please make sure that 

 

a suitable isolating switch is incorporated in the permanent wiring, mounted

 

and positioned to comply with the local wiring rules and regulations. The switch

 

must be of an approved type installed in the fixed wiring and have a contact separation in all poles 
that provide full disconnection under overvoltage category III conditions.

 

it is not installed and connected to flues where other appliances are installed

 

and which run off energy supplies other than electricity (eg water heaters, boilers,

 

gas cookers).

 

the power supply cable (type H05VV-F 3x0.75 mm

2

) is connected to terminals marked with

 

the letters L (power line) and N (neutral) mounted on the appliance and is secured

 

in position by a cable gland.

 

the power supply cable is connected to a suitable and easily accessible fixed power outlet or 
isolating switch.

 

the power outlet or isolating switch remains accessible after installation and the appliance can be

 

disconnected from the electricity supply.

 

exhaust air is not discharged into a heating flue or wall cavity, unless the cavity is designed for that 
purpose.

 

If you install using the external ducting through a side wall, ensure the surface area of the external 
venting grill is no smaller than 150 cm

2

.

 

the glass and stainless steel components are handled with care. These are easily damaged if abraded 
or knocked by tools.

1

IZONA VentSurface

Installation instructions

HC90 WALL models

NZ AU GB IE

(1,1)  -1- 599480D izona vswall install A2 NZGB.indd 21/7/09 2:42:47 PM

(1,1)  -1- 599480D izona vswall install A2 NZGB.indd 21/7/09 2:42:47 PM

Summary of Contents for IZONA HC90

Page 1: ... is to be ducted the flue is in good condition especially if it has been out of use for a long period of time If the air is to be ducted it will not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels the installation will comply with laws and regulations regarding ducting waste gases for optimal efficiency use smooth ducting for reduced noise and...

Page 2: ...ew holes in triangular mounting bracket 390 J length of power supply cable 1450 Installation diagrams for illustration purposes only GAS ELECTRIC Clearances mm HC90 A minimum clearance from bottom of VentSurface to trivets or pot support surface of gas cooktops pot support surface of electric cooktops including induction 750 650 Note to ensure that the VentSurface is able to perform at its best we...

Page 3: ...irculation Requires Carbon Filter to be purchased separately as part of the Ductless Recirculating Kit Contact your nearest Fisher Paykel Authorised Service Agent or www fisherpaykel com for instructions and details External ducting through a side wall or ceiling Recirculation recirculates filtered air back into the kitchen RATING PLATE LOCATION 6 Cod TYPE SERIE BATCH W Hz V W tot W MAX M2 L L 3 1...

Page 4: ...TTACH PLASTIC VENT DUCT ATTACH TRIANGULAR MOUNTING BRACKETS A B 6 mm holes 2 2 1 599480D izona vswall install A2 NZGB indd 21 7 09 2 42 47 PM 2 2 1 599480D izona vswall install A2 NZGB indd 21 7 09 2 42 47 PM ...

Page 5: ...P MOUNTING BRACKET ONTO WALL ATTACH FLUE COVER 9 A B A B 6 mm holes Important VERYHEAVY Ensurethatthe wallisabletowithstandthe totalweight 34kg ofthe appliancemountedonit 1 1 2 599480D izona vswall install A2 NZGB indd 21 7 09 2 43 07 PM 1 1 2 599480D izona vswall install A2 NZGB indd 21 7 09 2 43 07 PM ...

Page 6: ...ER MODE 11 After installation the VentSurface has to be set to operate on aluminium mesh filter mode if the extracted air is ducted outside or carbon filter mode if the extracted air is recirculated indoors To change between filter modes 1 Make sure the VentSurface is on stand by plugged into a power outlet which is switched on but the fan is off 2 Press the button 3a The display will show the sym...

Page 7: ...re a means of disconnection from the mains electricity supply disconnection switch or power outlet accessible to the customer after installation Have you removed the protective blue film from the stainless steel surfaces Is the VentSurface earthed OPERATION Have you informed the customer about the cleaning alerts Have you demonstrated the basic operation to the customer Installer s name Installer ...

Reviews: