background image

7

1

2

ATTACH PLASTIC VENT DUCT & ATTACH TRIANGULAR MOUNTING BRACKETS

A

B

 

6 mm holes

(2,2)  -1- 599480D izona vswall install A2 NZGB.indd 21/7/09 2:42:47 PM

(2,2)  -1- 599480D izona vswall install A2 NZGB.indd 21/7/09 2:42:47 PM

Summary of Contents for IZONA HC90

Page 1: ... is to be ducted the flue is in good condition especially if it has been out of use for a long period of time If the air is to be ducted it will not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels the installation will comply with laws and regulations regarding ducting waste gases for optimal efficiency use smooth ducting for reduced noise and...

Page 2: ...ew holes in triangular mounting bracket 390 J length of power supply cable 1450 Installation diagrams for illustration purposes only GAS ELECTRIC Clearances mm HC90 A minimum clearance from bottom of VentSurface to trivets or pot support surface of gas cooktops pot support surface of electric cooktops including induction 750 650 Note to ensure that the VentSurface is able to perform at its best we...

Page 3: ...irculation Requires Carbon Filter to be purchased separately as part of the Ductless Recirculating Kit Contact your nearest Fisher Paykel Authorised Service Agent or www fisherpaykel com for instructions and details External ducting through a side wall or ceiling Recirculation recirculates filtered air back into the kitchen RATING PLATE LOCATION 6 Cod TYPE SERIE BATCH W Hz V W tot W MAX M2 L L 3 1...

Page 4: ...TTACH PLASTIC VENT DUCT ATTACH TRIANGULAR MOUNTING BRACKETS A B 6 mm holes 2 2 1 599480D izona vswall install A2 NZGB indd 21 7 09 2 42 47 PM 2 2 1 599480D izona vswall install A2 NZGB indd 21 7 09 2 42 47 PM ...

Page 5: ...P MOUNTING BRACKET ONTO WALL ATTACH FLUE COVER 9 A B A B 6 mm holes Important VERYHEAVY Ensurethatthe wallisabletowithstandthe totalweight 34kg ofthe appliancemountedonit 1 1 2 599480D izona vswall install A2 NZGB indd 21 7 09 2 43 07 PM 1 1 2 599480D izona vswall install A2 NZGB indd 21 7 09 2 43 07 PM ...

Page 6: ...ER MODE 11 After installation the VentSurface has to be set to operate on aluminium mesh filter mode if the extracted air is ducted outside or carbon filter mode if the extracted air is recirculated indoors To change between filter modes 1 Make sure the VentSurface is on stand by plugged into a power outlet which is switched on but the fan is off 2 Press the button 3a The display will show the sym...

Page 7: ...re a means of disconnection from the mains electricity supply disconnection switch or power outlet accessible to the customer after installation Have you removed the protective blue film from the stainless steel surfaces Is the VentSurface earthed OPERATION Have you informed the customer about the cleaning alerts Have you demonstrated the basic operation to the customer Installer s name Installer ...

Reviews: