Service Manual 547226: OB30
December 2012
43
5.26
Determining which power module is faulty in a double oven
(F4 or F5 Fault Codes)
(Refer to Technical Overview Section 2.25)
Set up the double oven as if it were a single oven so that the faulty power module can
be eliminated.
PROCEDURE:
For Upper Cavity power module:
Figure 5.26
1. Unplug the purple harness from the clock module.
2. Remove the link harness to the lower cavity power module.
The clock module now assumes there is only one power module. The second
power module will run in a powered but disabled mode (elements will not operate).
3. Try to operate the upper cavity. If the fault code reappears then the upper cavity
power module is faulty and needs to be replaced. (refer to Servicing Instructions
Section 7.9)
If the fault code does not reappear, then the lower power module is faulty and needs
to be replaced.
Link Harness
12way clock harness module
Upper
Lower
Summary of Contents for OB30DDEPX1
Page 2: ......
Page 45: ...Service Manual 547226 OB30 December 2012 45 6 2 Single Oven Wiring Schematic ...
Page 47: ...Service Manual 547226 OB30 December 2012 47 Neutral Circuit ...
Page 48: ...Service Manual 547226 OB30 December 2012 48 Generic High Voltage Circuit ...
Page 49: ...Service Manual 547226 OB30 December 2012 49 Generic Low Voltage Lock Circuit ...
Page 50: ...Service Manual 547226 OB30 December 2012 50 Lighting and Earth Circuit ...
Page 52: ...Service Manual 547226 OB30 December 2012 52 Neutral Circuit ...
Page 53: ...Service Manual 547226 OB30 December 2012 53 Generic High Voltage Circuit ...
Page 54: ...Service Manual 547226 OB30 December 2012 54 Generic Low Voltage Lock Circuit ...
Page 55: ...Service Manual 547226 OB30 December 2012 55 Lighting Earth Circuit ...
Page 74: ...Service Manual 547226 OB30 December 2012 74 8 N O T E S ...