23
@0
GAS CONVERSION
Injectors table
BURNERS
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11” (279.4mm)
W.C.P.
NATURAL GAS
4” (101.6mm)
W.C.P.
BTU/HR
BTU/HR
Ø INJECTOR
[1/100 MM]
Ø INJECTOR
[1/100 MM]
Semirapid (SR)
7600
(LP/Propane Gas)
1800
78
–
8000
(Natural Gas)
1800
–
136
Triple Ring
12000
(LP/Propane Gas)
6300
97
–
14000
(Natural Gas)
6300
–
180
Dual (D)
Inner crown
2800
1
1100
1
47
3
80
3
Full burner
18000
2
6500
2
79 (x2)
4
135 (x2)
4
GAS GAS MODELS ONLY
Oven burner
17000
3200
120
208
Broil burner
13000
–
105
184
1
Power calculated only with inner crown operating
2
Power calculated with inner and outer crown operating
3
Inner crown injector
4
Outer crown injector
Replacing the cooktop burner injectors
●
Remove the pan supports, the burner caps and the flame spreaders.
●
Using a wrench substitute the nozzle injectors with those most
suitable for the kind of gas for which it is to be used.
●
Refit the flame spreaders, the burner caps and the pan supports.
The burners are designed so that no regulation of the primary air is
required.
Semi-rapid burner
Dual burner
Inner crown injector
Inner crown injector
Inner crown injector
Outer crown injector