Burners
Nominal Power [KW]
Reduced Power [KW]
LPG
G30 - 28-30 mbar
G31 - 37 mbar
Natural Gas
G20 - 20 mbar
Injector Dia.
[1/100 mm]
Injector Dia.
[1/100 mm]
(no. 2 outer)
(no. 2 outer)
(*) Power calculated with inner crown operating
(#) Power calculated with inner and outer crowns operating
Lubrication of the Gas Taps
A qualified technician must lubricate the gas taps.
• All intervention regarding installation maintenance and conversion of the appliance must be
fulfilled with original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
Connecting the Power Supply Cable
This cooker must be connected to the electricity supply only by an authorised person.
Feeder Cable Section
This cooker must be connected to electrical supply using H05RR-F insulated cable 220-240V~ 3 x 1,5 mm
2
cable.
To connect the Power Supply Cable to the Cooker, it is necessary to:
1. Unhook the terminal board cover by inserting a screwdriver into the two hooks ‘A’ (Fig. 14).
2. Unscrew the screw ‘D’ and open completely the cable clamp ‘E’ (Fig. 15).
3. Connect the phase, neutral and earth wires to terminal board ‘G’ according to the diagrams in Fig. 15.
4. Strain the feeder cable and block it with cable clamp ‘E’ (by screwing screw ‘D’).
5. Close the terminal block cover (check the two hooks ‘A’ are correctly hooked).
Updated: Thu, 26 Mar 2020 03:34:19 GMT