840653
41
Display Code: 3
Filter Sensor Cold.
Reason:
Faulty filter temperature sensor (the resistance is out of normal range: resistance
greater than 45K Ohms).
Action:
Check the resistance of the filter temperature sensor (refer to Section 8.1.14). If
faulty, replace.
Display Code: 4
Filter Sensor Hot.
Reason:
Faulty filter temperature sensor (the resistance is out of normal range: resistance less
than 660 Ohms).
Action:
Check the resistance of the filter temperature sensor (refer to Section 8.1.14). If
faulty, replace.
Display Code: 5
Defrost Sensor Cold.
Reason:
Faulty defrost temperature sensor (the resistance is out of normal range: resistance
greater than 45K Ohms).
Action:
Check the resistance of the defrost temperature sensor (refer to Section 8.1.14). If
faulty, replace.
Display Code: 6
Defrost Sensor Hot.
Reason:
Faulty defrost temperature sensor (the resistance is out of normal range: resistance
less than 660 Ohms).
Action:
Check the resistance of the defrost temperature sensor (refer to Section 8.1.14). If
faulty, replace.
Display Code: 7
Evaporator Inlet Sensor Cold.
Reason:
Faulty evaporator inlet temperature sensor (the resistance is out of normal range:
resistance greater than 45K Ohms).
Action:
Check the resistance of evaporator inlet temperature sensor (refer to Section 8.1.14).
If faulty, replace.
Display Code: 8
Evaporator Inlet Sensor Hot.
Reason:
Faulty evaporator inlet temperature sensor (the resistance is out of normal range:
resistance less than 660 Ohms).
Action:
Check resistance of the evaporator inlet temperature sensor (refer to Section 8.1.14).
If faulty, replace.
Display Code: 9
Evaporator Outlet Sensor Cold.
Reason:
Faulty evaporator outlet temperature sensor (the resistance is out of normal range:
resistance greater than 45K Ohms).
Action:
Check the resistance of the evaporator outlet temperature sensor (refer to Section
8.1.14). If faulty, replace.
Display Code: 10
Evaporator Outlet Sensor Hot.
Reason:
Faulty evaporator outlet temperature sensor (the resistance is out of normal range:
resistance less than 660 Ohms).
Action:
Check the resistance of the evaporator outlet temperature sensor (refer to Section
8.1.14). If faulty, replace.
Display Code: 11
Compartment Sensor Cold.
Reason:
Faulty compartment temperature sensor (the resistance is out of normal range:
resistance greater than 45K Ohms).
Action:
Check the resistance of the compartment temperature sensor (refer to Section
8.1.14). If faulty, replace.
Display Code: 12
Compartment Sensor Hot.
Reason:
Faulty compartment temperature sensor (the resistance is out of normal range:
resistance less than 660 Ohms)
Action:
Check the resistance of the compartment temperature sensor (refer to Section
8.1.14). If faulty, replace.
Summary of Contents for RB36S25MKIW
Page 1: ...840653 Service Manual CoolDrawer Models RB36S25MKIW RB90S64MKIW ...
Page 12: ...840653 12 3 4 Integrated Panel Preparation ...
Page 14: ...840653 14 3 5 Create Cut Outs In Frame 3 6 Locate And Secure Install Brackets ...
Page 15: ...840653 15 3 7 Attach Inlet And Outlet Vent Ducts 3 8 Attach Power Cord And Trim Brackets ...
Page 16: ...840653 16 3 9 Move Product Into Cavity 3 10 Fit Drawer Panel Attachment Hooks ...
Page 17: ...840653 17 3 11 Attach Drawer Panel To Front Of Drawer ...
Page 18: ...840653 18 3 12 Secure Trim Brackets To Cabinetry 3 13 Attach Trims To Sides Of Cabinetry ...
Page 19: ...840653 19 3 14 Attach False Panel 3 15 Check Operation ...
Page 53: ...840653 53 11 WIRING DIAGRAMS Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω ...
Page 54: ...840653 54 ...
Page 77: ...840653 77 ...