321037
66
Bale arm lever sensing if
ice bin is full. If the arm
cannot move down, the
icemaker will not harvest.
If bin is not full, icemaker
continues rotation to eject
ice.
Note 3.
With the RF175 model, the fault code for the icemaker is displayed not on the LCD display, but on
the icemaker PCB board as LED flashes. The PCB board is located in the power control module,
which is in turn located in the unit compartment. If the LED is flashing, this is the fault code. Refer
to the table below:
If a
fault
has
occur
red
relati
ng to
the
displa
y
board
, the
fault
code
will show on the display just like any other fault. The fault history is a tool to view intermittent
faults.
Note: There will be no alarm beeping if these faults occur.
Code Fault
F30
No display signal received (shorted or broken wire).
F31
No display signal received (shorted or broken wire) clock or data line.
Check Harness wiring under hinge cover
Note 4.
•
Is the icemaker gearbox iced up or frozen, i.e. has ice built up around it? This could be the
reason why it doesn’t rotate.
•
Check that the evaporator is defrosting and the defrost element is working along with the FC
fan. If not, thaw and retest.
•
Force a manual harvest.
Note 5.
If water doesn’t enter the tray:
Check - Is the water turned on to the cabinet? Can you dispense water through the door?
Check - Are there any kinks in the water lines?
Check - Is the water filter blocked?
Check - The water solenoid resistance.
Check - The resistance of the icemaker motor (refer to Section 12.1).
Check - That the solenoid is opening and water is leaving the solenoid.
Check - For blockage in the icemaker fill tube/nozzle.
12.1
Testing Icemaker Motor
Testing of the icemaker motor is carried out at the power module.
Code Fault
Action
0
(No LEDs)
No fault.
No fault with PCB board.
1
Motor timeout.
Check motor resistance. Is the
motor running?
2
Motor current high – motor
obstructed.
Check has gearbox frozen? Thaw
and test.
3
Temperature sensor too hot.
Check resistance of sensor. Refer
to table in Section 6.1.8.
4
Temperature sensor too cold (or
open circuit).
Replace open circuit sensor.
5
Water solenoid current high.
Check resistance of solenoid.
Replace if faulty.
Summary of Contents for RF175W
Page 1: ...321037 Service Manual Active Smart Refrigerator Freezer Models RF195A RF175W...
Page 19: ...321037 19 5 4 5 Condenser Mullion Layout Diagram 5 4 5...
Page 77: ...321037 77 15 WIRING DIAGRAM 15 1 RF175 Wiring Diagram...
Page 78: ...321037 78 15 2 RF175 Control Module Wiring Diagram...
Page 79: ...321037 79 15 3 RF175 Ice Water Wiring Diagram...
Page 80: ...321037 80 15 4 RF175 Ice Water Control Module Wiring Diagram...
Page 81: ...321037 81 15 5 RF195A Ice Water Wiring Diagram...
Page 82: ...321037 82 15 6 RF195A Ice Water Control Module Wiring Diagram...