321037
98
Refer to Section
17.13
Compressor will
not run and is cold
to touch.
Refer to Section
17.12
Compressor will
not run and is hot
to touch.
Refer to Section
17.11
Compressor runs
continuously.
Are there any
faults on the
LCD display?
Is
refrigeration
taking place?
Continue testing.
Check for loss of
gas (leak) or
blockage.
Check for correct fitting of
sensors. Check sensor
resistances.
Refer to Section
17.4
Check for loss of
gas (leak) or
blockage.
Yes
Yes
No
No
No
Are the FC/PC
reaching set
temperatures?
Yes
No
17.10 Compressor
Faults
17.11
Compressor Runs Continuously
Summary of Contents for RF175W
Page 1: ...321037 Service Manual Active Smart Refrigerator Freezer Models RF195A RF175W...
Page 19: ...321037 19 5 4 5 Condenser Mullion Layout Diagram 5 4 5...
Page 77: ...321037 77 15 WIRING DIAGRAM 15 1 RF175 Wiring Diagram...
Page 78: ...321037 78 15 2 RF175 Control Module Wiring Diagram...
Page 79: ...321037 79 15 3 RF175 Ice Water Wiring Diagram...
Page 80: ...321037 80 15 4 RF175 Ice Water Control Module Wiring Diagram...
Page 81: ...321037 81 15 5 RF195A Ice Water Wiring Diagram...
Page 82: ...321037 82 15 6 RF195A Ice Water Control Module Wiring Diagram...