11
CAVITY PREPARATION
NOTE: Left hand hinge is a mirrored version of the image shown.
For ease of installation, ensure cavity has consistent dimensions
top to bottom and left to right.
Minimum Cavity Dimensions
mm
a
Overall height of cavity
1880
B
Overall width of cavity
600
c
Minimum overall depth of cavity:
• When services are located outside of cavity (shallow)
• When services are located in the cabinet above the cavity
• When services are located at rear of cavity (deep)
600
610
650
Minimum required finished return
100
Electrical / Plumbing Supply Dimensions
mm
d
Overall height of supply routing area at rear of cavity
37
Overall width of supply routing area at rear of cavity
600
E
Overall depth of supply routing area at rear of cavity
20
F
Height of notch at rear of cavity for services to be routed into
adjacent cabinet (either side)
100
G
Depth of notch at rear of cavity for services to be routed into
adjacent cabinet (either side)
55
H
Minimum depth above cavity for services to be routed through
55
Recommended that services are routed to the adjacent cabinet or either side
of the product.
Dimensions may vary by ±2mm
FINISHED RETURN
CAVITY SIDES & TOP
ALTERNATIVE AREA
ABOVE CAVITY FOR
ELEC / WATER CONNECTION
B
C
100
A
D
E
ISO VIEW
G
F
H
Summary of Contents for RS6019F2L