321023
73
10 GENERAL
TROUBLESHOOTING
This troubleshooting chart on the following pages contains symptoms that may be seen in
malfunctioning units. Each symptom is accompanied by one or more possible causes and by a
possible remedy or test to determine if components are working properly.
Symptom Possible
Causes
Corrective
Action
Unit does not run.
No power to unit.
Check for power at outlet. Check fuse
box/circuit breaker for blown fuse or tripped
breaker. Replace or reset.
Faulty power cord.
Check with test light at unit. If no circuit
and current is indicated at outlet, replace or
repair.
Low voltage.
Check input voltage for proper voltage.
Take appropriate action to correct voltage
supply problem.
Faulty motor or freezer temperature
control.
Check all connections are tight and secure.
Jumper across terminals of control. If unit
runs, replace control.
Faulty
relay.
Check relay. Replace if necessary.
Faulty compressor.
Is the cabiinet in defrost Mode?
Check compressor motor windings for
opens/shorts.
Wait 8 minutes 30 seconds with power on
to cabinet.
Perform compressor direct wiring test.
Replace if necessary.
Faulty overload.
Check overload for continuity.
NOTE:
Ensure compressor/overload are
below trip temperature before testing.
Replace if necessary.
Fresh food compartment too warm.
Excessive door opening.
Consumer education.
Overloading of shelves. Consumer
education.
Warm or hot foods placed in cabinet.
Consumer education.
Cold control set too warm.
Set control to colder setting.
Poor door seal.
Level cabinet. Adjust hinges. Replace
gasket.
Fresh food compartment airflow.
Check damper is opening by removing
grille. With door open, damper should
open. Replace if faulty.
Turn control knob to colder position or can
be tested in diagnostics.
Interior light remains on.
Check switch. Replace if necessary.
Faulty condenser fan or evaporator fan. Check fan and wiring. Replace if
necessary.
Faulty compressor.
Replace compressor.
Fresh food compartment too cold.
Fresh food compartment temperature
control set too cold.
Adjust fresh food compartment
temperature control.
Fresh food compartment airflow not
properly adjusted.
Check air flow.
Freezer and provision sections too
Temperature controls set too warm.
Reset temperature controls.
warm.
Poor door seal.
Level cabinet. Adjust hinges. Replace
gasket.
Dirty condenser or obstructed grille.
Check condenser and grille. Clean.
Faulty control.
Test control. Replace if failed.
Refrigerant shortage or restriction.
Check for leak or restriction. Repair,
evacuate and recharge system.
Freezer section too cold.
Freezer temp control set too cold.
Adjust freezer temperature control.
Faulty control.
Test control. Replace if failed.
Cold control capillary not properly
clamped to evaporator.
Reposition clamp and tighten.
Summary of Contents for RX256DT4X1
Page 11: ...321023 11 2 3 Refrigerant Flow...
Page 12: ...321023 12 2 4 Cabinet Air Flow...
Page 13: ...321023 13 2 5 Ice And Water Dispenser Diagram...
Page 14: ...321023 14 2 6 Water Valve Diagram...
Page 15: ...321023 15 2 7 Typical External Sweat Pattern...
Page 16: ...321023 16 3 INSTALLATION...
Page 17: ...321023 17...
Page 18: ...321023 18...
Page 76: ...321023 76 Ice Water Dispensing Board...
Page 78: ...321023 78 Mid Electronic Specification Control RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 104: ...321023 104 14 WIRING DIAGRAMS 14 1 Wiring Schematic RX256DT7X1...
Page 105: ...321023 105 14 2 Wiring Diagram RX256DT7X1...
Page 106: ...321023 106 14 3 Wiring Schematic RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 107: ...321023 107 14 4 Wiring Diagram RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 108: ...321023 108 NOTES...