321023
84
11.3.2
Condenser Fan Motor and Blade
1. Remove the machine compartment hex screws.
2. Remove
the
cover.
3. Disconnect the wiring harness connector from the condenser motor.
4. Remove the hex screws from the mounting brackets attached to the motor.
5. Remove the motor and fan blade out the rear of the shroud.
6. Remove the retainer nut to remove the fan blade.
7. Reverse the procedure to reassemble.
11.3.3 Compressor
1. Remove the machine compartment hex screws.
2. Remove
the
cover.
3. Remove the bale strap that retains the overload/relay/capacitor.
4. Pull
the
overload/relay/capacitor
assembly off the compressor terminals.
5. Disconnect the ground wires attached to the compressor.
6. Follow the reclaiming procedures in Section 13 of this manual.
7. Remove
the
drier.
8. Unbraze the low and high pressure lines at the compressor.
9. Remove the compressor mounting bolts.
10. Lift the compressor out of the unit.
NOTE:
Install the new drier and compressor as per instructions in Section 13. Evacuate and
recharge the sealed system as per instructions in Section 13.
11.3.4
Condensate Drain Tube
1. Remove the machine compartment hex screws.
2. Remove
the
cover.
3. Locate and remove the hex screw holding the drain tube in place.
4. Remove the drain tube by pulling down on the tube.
5. Reverse the procedure to reassemble
11.3.5
Condensate Drain Pan
NOTE:
The condensate drip pan may spill when steps 1 thru 4 are performed. Have a towel ready to
mop up any spillage.
1. Remove the machine compartment and water valve cover hex screws.
2. Remove
the
covers.
3. Remove the screws holding the condenser shroud to the base pan.
4. Raise the rear of unit up about 75mm and block up.
5. Remove the two rear torx head screws holding the rear of the base pan to the cabinet (located under
the base pan).
6. Lower the cabinet back to the floor after removing the blocks.
7. Raise the cabinet off the base pan enough to allow removal of the condenser shroud. Disconnect
any wiring attached to the shroud to ease removal of the shroud.
8. After the shroud is removed, bend the copper tubing up out of the condensate pan to allow removal
of the condensate pan.
9. Reverse the procedure to reassemble.
11.3.6 Overload/Relay
1. Remove the machine compartment hex screws.
2. Discharge the capacitor (if unit is so equipped) through a 10.000-ohm resistor.
3. Using fingers and a standard screwdriver, press and pry the bale strap off the
overload/relay/capacitor assembly.
4. Reverse the procedure to reassemble.
Summary of Contents for RX256DT4X1
Page 11: ...321023 11 2 3 Refrigerant Flow...
Page 12: ...321023 12 2 4 Cabinet Air Flow...
Page 13: ...321023 13 2 5 Ice And Water Dispenser Diagram...
Page 14: ...321023 14 2 6 Water Valve Diagram...
Page 15: ...321023 15 2 7 Typical External Sweat Pattern...
Page 16: ...321023 16 3 INSTALLATION...
Page 17: ...321023 17...
Page 18: ...321023 18...
Page 76: ...321023 76 Ice Water Dispensing Board...
Page 78: ...321023 78 Mid Electronic Specification Control RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 104: ...321023 104 14 WIRING DIAGRAMS 14 1 Wiring Schematic RX256DT7X1...
Page 105: ...321023 105 14 2 Wiring Diagram RX256DT7X1...
Page 106: ...321023 106 14 3 Wiring Schematic RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 107: ...321023 107 14 4 Wiring Diagram RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 108: ...321023 108 NOTES...