- 55 -
Locating slot
Spike
6.33 Removal of Fan
(a) Follow instructions for removal of the motor. (Refer to
Section 6.32)
(b) Remove the circlip securing the fan to the motor shaft.
(c) While sitting in a chair, place feet on top of the base of
the fan and pull upwards on the motor. This will pull
the motor shaft out of the spline in the fan.
Reassembly
(a) Refit in reverse manner, lining up the spline on the
motor shaft with the spline in the fan and pushing the
motor shaft into the fan boss sufficiently to refit the fan
retaining circlip.
Do not hit the motor shaft.
(b) Refit the circlip to the motor shaft.
6.34 Removal of Fan Motor Housing
(a) Follow instructions for removal of the motor. (Refer to
Section 6.32)
(b) Use fingers to unclip the three clips from the centre beam.
Spring the housing off over the centre beam, tilt horizontally
and unhook from the rear beam.
Reassembly
(a) With the housing horizontal, hook it over the rear beam and
tilt it down to rest on the centre beam.
(b) Slide the housing on the beam to allow the spring clip to
engage the slot in the rear beam.
(c)
Press on the housing to spring it over the centre beam (check
that the locating spike is engaged in the locating slot in the
centre beam).
(d)
Press on the housing at three lug locations to snap the three
clips over the centre beam.
Spring clip in slot