background image

4

37

According to FCC part 15.21 Changes or Modifications made to this device not expressly approved by

the party responsible for compliance could void the users authority to operate this equipment.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may cause undesired
operation of the device.

This radio transmitter 8188A-GB has been approved by Industry Canada to operate with the
antenna types listed below with the maximum permissible gain and required antenna
impedance for each antenna type indicated. Antenna types not included in this list, having a
gain greater than the maximum gain indicated for that type, are strictly prohibited for use with
this device.

Antennas:

1.

5” DD Coil, Part Number 5COIL-GBUG

2.

11” DD Coil, Part Number 11COIL-GB

Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1)
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.

Le présent émetteur radio 8188A-GB a été approuvé par Industrie Canada pour fonctionner
avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et
l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette
liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour
l’exploitation de l’émetteur.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour
l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité
nécessaire à l’établissement d’une communication satisfaisante.

Introduction to the Gold Bug

DP

DEEP PENETRATING GOLD NUGGET HUNTER

The New Gold Bug™ DP is unique among gold prospecting metal detectors for
its combination of high sensitivity to small gold nuggets and its versatile
function as an all-purpose treasure detector.

The controls and features are tailored to gold prospecting, including a
sophisticated ground balancing system, separate control over signal gain and
threshold, and a unique discrimination control system.  These features also
make for a great relic-hunting detector.  While the Gold Bug™ DP makes for a
highly competent coin-shooting detector, its user interface and features are not
specifically designed for this purpose.  As a coin-shooter, you will notice that
the Gold Bug™ DP exhibits slightly lower sensitivity to high-conductivity coins,
like a U.S. quarter; this is a result of its specialized design to emphasize
sensitivity to small, low conductivity metals like gold nuggets.

Congratulations!

Congratulations on your purchase of the new Gold Bug™ DP metal detector. The newly
designed Gold Bug™ DP has been custom designed to find small gold nuggets, but
unlike other specialized gold prospecting detectors, it can also be used for relic hunting
and coin shooting.
Whether you use your Detector in your backyard, at the shoreline, in the mountains or
fields afar, your investment will let you experience the excitement of searching for yet
uncovered treasures and give you hours and years of outdoor enjoyment. Out on your
own or with a group, places to use your Gold Bug™ DP are unlimited as buried
treasures can be as near as your doorstep or as far as you wish to travel.
This manual has been written to help you get optimal use of your detector, so we hope
you will read it thoroughly before your first outing and will also refer back to this manual
from time to time to reinforce features and methods as you become more proficient in
the field.
Happy Hunting from Fisher Research Labs!

Summary of Contents for Gold Bug DP

Page 1: ...its all FCAP Replacement Accessory Search Coils 11 DD Standard Coil 11COIL GB 199 95 5 DD Accessory Coil 5COIL GBUG 159 95 Coil Covers Specially made to protect your coil from abrasion and damage 11 D...

Page 2: ...2 39...

Page 3: ...Objects 12 EMI 12 Operation and Controls 13 Control Panel 13 Control Knobs Off On Gain 14 Disc All Metal Threshold 15 Touchpad Controls GG Pinpoint 15 and 15 Operating in All Metal Mode Ground Grab G...

Page 4: ...adio peut fonctionner avec une antenne d un type et d un gain maximal ou inf rieur approuv pour l metteur par Industrie Canada Dans le but de r duire les risques de brouillage radio lectrique l intent...

Page 5: ...fferent tones for different types of metals and when the detector eliminates certain metals we refer to this as the detector discriminating among different types of metals Discrimination is an essenti...

Page 6: ...d dispose of any and all trash and litter found Appreciate and protect our inheritance of natural resources wildlife and private property Act as an ambassador for the hobby use thoughtfulness consider...

Page 7: ...ovided one on the Lower Stem close to the Searchcoil and one on the Upper Stem close to the housing Leave just enough slack in the Cable at the Searchcoil end to be able to rotate the Searchcoil a sma...

Page 8: ...ndicator at the bottom of the display indicates the battery condition The detector requires a single 9 volt ALKALINE battery Do not use ordinary zinc carbon batteries Do not use Heavy Duty batteries R...

Page 9: ...rface Never swing the searchcoil like a pendulum WRONG CORRECT QUICK START DEMONSTRATION I Supplies Needed a Nail a Zinc Penny dated after 1982 a Nickel a Quarter II Position the Detector a Place the...

Page 10: ...termittent nature than electrical interference The second most common cause is a loose searchcoil connector The noise from a loose connector will usually be very erratic or intermittent in nature Try...

Page 11: ...ect metal detectors Overall the potential for electromagnetic interference is greater than it was just a few years ago Modern high end metal detectors are a lot more sensitive than older units this al...

Page 12: ...always carry a magnet to help discriminate gold from hot rocks and iron Gold will not be attracted to a magnet Pieces of iron will always be attracted to a magnet Negative hot rocks will almost alway...

Page 13: ...e gold areas a lot of the terrain is under claim so you need to learn how to recognize posted claims and stay off of them unless you have the claim owner s permission Prospecting clubs such as the Gol...

Page 14: ...e the loss of sensitivity resulting from discrimination is enough to cause those little nuggets to vanish If you have gone many hours without finding gold and are wondering if there is something wrong...

Page 15: ...nd its distance from the searchcoil As a starting point refer to the table below T TA AR RG GE ET T R Re ea ad do ou ut t The table below lists some common approximate target values With experience in...

Page 16: ...sed to find all types of metal objects in the ground The searchcoil must be in motion for objects to be detected Ground Grab GG Naturally occurring minerals in soil look like metal to a metal detector...

Page 17: ...g it difficult to know where it is located It will not have the sound and feel of a metal object GROUND BALANCING Reading the Display Most gold prospecting and relic hunting is done by ear Listen for...

Page 18: ...ll be achieved by first performing the GG procedure in All Metal mode The ground balance setting achieved using GG will carry over into this mode Setting the Controls As you adjust any of the controls...

Page 19: ...increase with target strength The approximate target depth in inches will be indicated in the center of the screen The depth scale is calibrated to coin sized objects Relative depth is indicated for l...

Page 20: ...20 will NOT BE DETECTED Values from 20 to 49 will induce a LOW tone Values from 50 to 100 will induce V C O tones see p 25 Suggestion Try changing the settings watch the screen and pass objects over t...