Gap Angle
: Sets the angle (degrees) duration that the motor will continue to rotate
for after the “Pulse Angle”. No fluid material is dispensed during the gap angle.
Rotation Delay
: Sets the time (seconds) before the motor starts rotating, once
the Z-Axis drive cylinder reaches the “DOWN” position. Fluid material is
dispensed during the rotation delay time.
This parameter can be used,
- when dispensing micro fluid beads and there is a need to ensure the Z-
Axis drive cylinder is in an absolute stationary position before fluid is
dispensed onto the workpiece.
- When dispensing a high viscosity fluid material and there is a need to wait
for the fluid to be dispensed out of the dispense tip and make contact with
the workpiece.
Dispense Delay:
Sets the time (seconds) after the motor starts rotating, that fluid
material will not be dispensed.
This parameter can be used when dispensing micro beads of low viscosity fluid
materials and there is a need to eliminate a buildup of material at the start of the
dispensing sequence onto the workpiece.
Rotation Speed
: Sets the speed (rpm) that the motor will rotate at during the
Dispense Delay, Dispense Angle and Gap Angle sequence.
A timing diagram is shown below of how all the parameters work together within
a program cycle.
Summary of Contents for F1300N.2
Page 1: ...F1300N 2 Rotary Table Operating Manual info fisnar com www fisnar com ...
Page 55: ...F1300N 2 Rotary Table Operating Manual 2022 Fisnar 55 F1300N 2 Rev 01 SPARE PARTS LIST ...
Page 57: ...F1300N 2 Rotary Table Operating Manual 2022 Fisnar 57 F1300N 2 Rev 01 MACHINE DRAWING ...
Page 59: ...F1300N 2 Rotary Table Operating Manual 2022 Fisnar 59 F1300N 2 Rev 01 TURNTABLE DRAWING ...
Page 63: ...F1300N 2 Rotary Table Operating Manual 2022 Fisnar 63 F1300N 2 Rev 01 NOTES ...