1.
F1 (Point Menu)
Below is a list of functions which are found under the
F1/ENTER
key. These functions are
„point-type‟ functions, meaning that the values applied will occupy one memory address.
Please see
for additional programming examples.
1.1
Dispense Dot
Registers the current XYZ location as a dispense point for dot dispensing.
The dispense time and wait time must be set in a previous memory address by registering
a
Point Dispense Setup
instruction.
The upward motion of the tip after dispensing can be controlled by registering a
Dispense
End Setup
instruction and / or a
Z Clearance
instruction in a previous memory address.
Dispense End Setup
and
Z Clearance
instructions are registered using the
F4 (SETUP)
key.
See also
,
Setup)
and
1.2
Line Start
Registers the current XYZ location as a Line Start point for line dispensing.
The line speed must be set in a previous memory address by registering a
Line
Speed
instruction using the
F4 (
SETUP)
key.
Dispense delay times used at Line Start and Line End points can be controlled by
registering a
Line Dispense Setup
instruction in a previous memory address. The
Line
Dispense Setup
instruction is registered by pressing the
F4
(SETUP)
key.
See also
.
Summary of Contents for F400N Series