F4000N Series Operating Manual
Section 5: Point Type & Function Reference
Part # 562187N-1
Rev. D Sep 2012
75
© 2012 Fisnar Inc.
The value will be used for all lines from the current memory address forward until another
Tail Length
instruction is found.
Values for the
Head Time
and
Tail Time
used when performing line dispensing are
registered by pressing the
F4 (Setup)
key, then selecting
Line Dispense Setup
.
The set
values will be used by all lines from that memory address forward until new set of
Line
Dispense Setup
values are found.
Line Dispense Setup
instruction.
5.3
Point Dispense Setup
Registers POINT DISPENSE SETUP values which set dispensing time and waiting time at
the end of dispensing („tail‟ time) for dots. The registered values will be used from the
current memory address forward until another POINT DISPENSE SETUP instruction is
found.
5.4
Dispense End Setup
Dispense End Setup
allows the
L.Length
,
L. Speed
and
H. Speed
values to be registered
at a memory address. These values will effect how far and how fast the tip rises after
dispensing.
After dispensing a dot or line, it is often required to raise the tip a short distance at a slow
speed. This allows the material to cleanly break free from the tip, without „dragging‟
material where it is not wanted.
Dispenser Turns Off here
Tip continues moving to end of line
Tail Length