background image

I&J7000 / RS232 COMMAND LIST 
Rev. D Feb 05 

Page 1 of 1 

 

 

 
Description: 

 
The PC Command list allows the I&J7000 series to be controlled by commands 
sent through the RS232 port. 
 
For example, it is possible to use HYPER-TERMINAL (included with Windows) to 
send the commands found on page three to drive the robot. 
 
 

Communication Parameters: 

 
BAUD RATE:  

115,200 

DATA BITS:   

PARITY: 

 

NONE 

STOP BITS:   

FLOW CONTROL:  HARDWARE 
 

• 

Be sure to use a NULL MODEM adapter when connecting the RS232 cable to 
the robot. 

 

• 

An RS232 cable and NULL MODEM adapter are supplied with the robot. 

 

• 

When using HYPER-TERMINAL to control the robot, it is recommended that 
you check the 

Echo Typed characters locally

 checkbox found under 

File, 

Properties, Settings, ASCII Setup

. This will ensure that you can see the 

commands as you type them. 

 

• 

All commands should be sent in CAPITAL CASE letters. 

 

• 

When a command is acknowledged, the robot will return 

OK!

 

 
 

Robot Setup: 

 
To setup the robot to accept commands over the RS232 cable: 
 
1.  Change the 

RUN MODE 

software setting on the robot teaching box to SLAVE 

MODE. The setting can be changed by pressing: 

 

MENU1  

è 

        (to change to page 2)  

1.  RUN MODE 
2.  SLAVE MODE 

 
2.  Change the TEACH / RUN mode switch on the robot front panel to RUN 

mode. 