background image

Installation Instructions

005720D Rev D

Page 18 of 20

Series 7 AdjusTables

w

w

w

.

d

e

t

a

i

l

s

-

w

o

r

k

t

o

o

l

s

.

c

o

m

FitWork

 Sit-to-Walkstation

Pull console forward.

11

Connect safety key to magnetic
attachment area on
front of keypad.

12

GLIDE

Before use, the table must be completely leveled, front-to back and side-to-side.

Coordinating the Lifting Columns

Prior to initial use of the height adjustment function you must "synchronize the system".

The installers who setup the worksurface may have already done so, but it's OK to repeat this function.

Synchronize the System

• Press the Down arrow until the worksurface comes to a stop at the lowest position.

• Release the Down arrow.

• Press and hold the down arrow for approximately 5 seconds while the table

synchronizes itself. The surface will lower itself approximately 5mm, then rise

approximately 5mm and finally settle back to its lowest position.

NOTE:

 It may be necessary to repeat the synchronization process more than once.

After performing this function, the movement of all lift columns connected is coordinated.

In the unlikely event that an error occurs, reset the control unit by pressing the Up and

Down buttons at the same time for 5 seconds. Then repeat the synchronizing sequence

as previously outlined above.

13

14

Raise or lower desk height
by pressing buttons on the
console.

NOTE:

 Guidelines on Moving the Table, see page 19.

For Wiring Guide, see page 20.

Summary of Contents for Walkstation A7TG660606H

Page 1: ... D Page 1 of 20 2007OfficeDetailsInc Allrightsreserved PrintedinU S A 2 09 P O Box 1967 CD 5E Grand Rapids MI 49501 1967 www details worktools com 2 Phillips Bit with Extension Tools Required Series 7 AdjusTables FitWork Walkstation 7 16 10mm Socket Wrench A7TG660606H A7TR663232H A7TG660632H A7TR383030H A7TG663206H A7TR782929H ...

Page 2: ...ront Once each lift column has been engaged lightly tap each connection point with a rubber mallet 1 8 1 4 inch at a time until completely seated Do not completely install one lift column at a time they must be installed incrementally Notes A clean abrasion free surface will be necessary for table assembly Worksurface Assembly NOTCH RIGHT COLUMN LEFT COLUMN STRETCHER FLUSH DOVETAIL DOVETAIL COLUMN...

Page 3: ...4 corners of the attachment plate Don t install all fasteners until the unit has been operated through one cycle Step 13 Installation Instructions 005720D Rev D Page 3 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m PHILLIPS HEAD SCREW 4mm HEX HEAD FASTENERS ATTACHMENT PLATE Locate and install each attachment plate using 4mm hex head fasteners provided Ti...

Page 4: ...r treadmill receiver onto legs and attach using four 4 screws on each leg Installation Instructions 005720D Rev D Page 4 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m TREADMILL RECEIVER SCREW 8 9 ...

Page 5: ...rol box in the predetermined location using pre drilled holes Installation Instructions 005720D Rev D Page 5 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m 10 CONTROL BOX ...

Page 6: ...next to console making sure holes in bracket are lined up with pilot holes on worksurface c Secure bracket to worksurface using three 3 screws d Secure brackets to each side of console using two 2 nuts and two 2 flat washers e Installation Instructions 005720D Rev D Page 6 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m 11 SHOULDER WASHER CONSOLE SHOULDER...

Page 7: ... the control box Route these cables in the wire management cableway provided Refer to the Wiring Guide for more information For best wire management connect lift columns to the closest port on the control box Installation Instructions 005720D Rev D Page 7 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m WIRE MANAGER 13 12 5 PORT 1 PORT 2 ...

Page 8: ...in clip Plug the cord into an outlet and check for binding then lower to the bottom and unplug unit Install the remaining fasteners in each of the remaining holes and tighten ALL screws securely Do not over tighten Installation Instructions 005720D Rev D Page 8 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m CABLE FROM CONSOLE CONTROL BOX 14 15 PLUG CONTR...

Page 9: ...mill Align treadmill with unit as shown Make sure the two 2 treadmill feet are inserted into the two 2 holes in the treadmill receiver NOTE The holes in the treadmill receiver are for the treadmill feet not the treadmill wheels Installation Instructions 005720D Rev D Page 9 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m HOLE IN TREADMILL RECEIVER 17 16 T...

Page 10: ...ke sure treadmill is turned on c NOTE for a b Be sure to secure signal cable to the console and treadmill with the screws integral to the cable connector This will ensure a good connection Installation Instructions 005720D Rev D Page 10 of 20 Series 7 AdjusTables FitWork Walkstation w w w d e t a i l s w o r k t o o l s c o m REAR OF TREADMILL 18 SIGNAL CABLE CONSOLE View from Underneath Worksurfa...

Page 11: ...m and finally settle back to its lowest position NOTE It may be necessary to repeat the synchronization process more than once After performing this function the movement of all lift columns connected is coordinated In the unlikely event that an error occurs reset the control unit by pressing the Up and Down buttons at the same time for 5 seconds Then repeat the synchronizing sequence as previousl...

Page 12: ...s until the unit has been operated through one cycle Step 18 Installation Instructions 005720D Rev D Page 12 of 20 Series 7 AdjusTables w w w d e t a i l s w o r k t o o l s c o m PHILLIPS HEAD SCREW 1 2 Sit to Walkstation Worksurface Assembly If you want the treadmill placed on the right side use these pilot holes for attaching legs If you want the treadmill placed on the left side use these pilo...

Page 13: ...talled left side installation shown Lower treadmill receiver onto leg and attach using four 4 screws Installation Instructions 005720D Rev D Page 13 of 20 Series 7 AdjusTables w w w d e t a i l s w o r k t o o l s c o m SIT WALK TREADMILL RECEIVER 3 4 SCREW SCREW FitWork Sit to Walkstation ...

Page 14: ... the controller to the underside of the worksurface towards the middle of the worksurface as shown Installation Instructions 005720D Rev D Page 14 of 20 Series 7 AdjusTables w w w d e t a i l s w o r k t o o l s c o m 5 6 FitWork Sit to Walkstation ...

Page 15: ...nd stick to worksurface Place wire into each wire keeper Repeat steps 14 15 on page 8 Installation Instructions 005720D Rev D Page 15 of 20 Series 7 AdjusTables w w w d e t a i l s w o r k t o o l s c o m CONTROL WIRE WIRE KEEPER 7 PAPER BACKING FitWork Sit to Walkstation ...

Page 16: ...tWork Sit to Walkstation w w w d e t a i l s w o r k t o o l s c o m 8 Carefully turn the table over 2 person operation NOTE Do NOT use either lift column as a brace when turning the table over as this may cause binding The top must be lifted free rotated and set down carefully ...

Page 17: ...readmill wheels Plug in cable from back of treadmill to back of console as shown on step 18 on page 10 Also plug cord of the table and the treadmill into an outlet make sure the treadmill is on as shown on step 18 on page 10 Installation Instructions 005720D Rev D Page 17 of 20 Series 7 AdjusTables w w w d e t a i l s w o r k t o o l s c o m FitWork Sit to Walkstation RECEIVER 9 10 HOLE IN TREADMI...

Page 18: ...orksurface comes to a stop at the lowest position Release the Down arrow Press and hold the down arrow for approximately 5 seconds while the table synchronizes itself The surface will lower itself approximately 5mm then rise approximately 5mm and finally settle back to its lowest position NOTE It may be necessary to repeat the synchronization process more than once After performing this function t...

Page 19: ...aken to ensure no side pressure is placed on any of the legs as it is tipped into position during transport and when tipped off the pallet at the new location Before in use in the location the table must again be completely leveled side to side and front to back Failure to do so may cause binding of the leg s and failure to operate properly After moving the legs must be re synchronized by holding ...

Page 20: ...u have completed the wiring use the Wire Management Cableways to hold all the cables and minimize possible entanglements NOTE Cableways and vertical wire management solutions are also available from Details Contact us for more information Installation Instructions 005720D Rev D Page 20 of 20 Series 7 AdjusTables w w w d e t a i l s w o r k t o o l s c o m FitWork Sit to Walkstation Wiring Guide 1 ...