HORIZONTAL WINDLASS MANUAL
VOLUME ONE
5.2 Wiring
5.2 Wiring
Plan the installation to suit the controls and give the operator a full view of the windlass. The
wiring system should be of the fully insulated type, which avoids possible electrolytic corrosion
problems.
We recommend the use of type III stranded, tinned copper wire with copper crimp
terminals (
NOTE
: we recommend that the cable are shorter if possible.
). Most modern installa-
tions are negative return (negative ground) but polarity should be checked. Overload protec
-
tion, in the form of the circuit breaker provided must be built into the windlass wiring circuit.
• Circuit breaker supplied:
Atlantic 600 Series (Circuit Breaker: 60 Amps - 80 Amps)
Atlantic 900 Series (Circuit Breaker: 80 Amps)
• The circuit breaker should be positioned close to the battery in a dry, readily accessible place.
• The breaker must be manually reset should an overload occur that causes it to trip to the off
position.
Warning
If you are not sure you understand these guidelines, seek professional help. Ensure that the
installation complies with USCG, ABYC, NMMA or other local regulations.
5.3 Control switch installation
5.3 Control switch installation
The unit is supplied with
Visit
www.five-oceans.com
for more information
Contactor box (
should be located within an dry area
) and control box used in some installation
refer to wiring diagram S 5.4