CLEANING INSTRUCTIONS

 

 

The prefilter and collecting cell must be washed on a regular 
basis  for  the  Air  Cleaner  to  function  at  its  peak  efficiency.  
The frequency of cleaning will vary from one environment to 
another,  therefore  the  cell  should  be  checked  monthly  to 
determine cleaning schedule.  On average, the cell should be 
washed every 2-3 months. 

 
COLLECTING CELL AND PREFILTER

 

1.  Turn  Air  Cleaner 

OFF

.    Remove  prefilter  and  collecting 

cell from the Air Cleaner. 

2.  Rinse prefilter  and  cell,  and  spray  completely  with  DAX 

Detergent (or non-chlorine, non-corrosive, non-abrasive, 
non-ammonia, liquid household detergent).  Let stand for 
5  minutes.    Rinse  well  with  hot  water  (120°F  /  49°C 
maximum). Repeat process 3 times. 

3.  If  dirt  remains,  let  cell  soak  in  a  solution  of  DAX 

Detergent and hot water for 30 minutes. 

4.  For  drying,  place  the  cell  on  a  45°  angle  on  one  end, 

with the arrow pointing sideways, and let stand for 10-24 
hours.    A  hair  dryer  may  be  used  to  speed  up  drying 
time.    Make  sure  the  cell  is  completely  dry  before 
reinserting back into Air Cleaner. 

5.  If arcing or snapping occurs or the lights do not come on 

when  the  cell  is  placed  back  in  the  unit  and  turned  on, 
then remove the cell and allow to dry longer. 

 

CARBON FILTER 

1.  The carbon filter must be replaced at regular intervals if 

odor  removal  is  desired  (approximately  every  3-6 
months). 

 

ODOR REMOVAL FILTERS ARE NOT WASHABLE.

 

 

CABINET

 

1.  Turn Air Cleaner 

OFF

2.  A soft, damp, lint-free cloth may be used to remove dirt 

and  fingerprints  from  painted  surfaces,  grills  and  side 
panels. 

NEVER  USE  AN  ABRASIVE  CLEANER  ON  THE 
CABINET. 

 

WARNING 

DO 

NOT 

WASH 

COLLECTING 

CELL 

IN 

DISHWASHER

.

 

Never use any object to clean between the cell plates as 
this may cause damage to the plates or ionizing wires. 
Never place the cell in an oven to dry. 
The edges of the cell may be sharp — handle with care. 

 
 
 
 
 
 
 
 
 
 
 

 
 

DAX Detergent and Carbon Filters are available from your Dealer. 

 

TROUBLESHOOTING CHART 

The  Performance  Indicator  Light  is  also  used  as  the  high 
voltage  fault  indicator.    If  the  fan  is  operating,  but  the  light 
does not come on, then there is a problem in the high voltage 
circuit.  To determine the problem, turn the Air Cleaner 

OFF 

and remove the collecting cell.  Close the door and turn the 
Air Cleaner back 

ON

.  If the light comes back on, the problem 

lies in the cell.  Check the cell for wetness from washing or 
look for a broken ionizing wire or bent cell plate(s). 
 
If  the  Performance  Light  does  not  come  on,  the  problem  is 
with the power board or Performance Light.  If you are unable 
to  correct  any  of  the  above  problems,  call  toll  free  North 
A m e r i c a  

1 - 8 0 0 - 2 6 7 - 8 3 0 5  

o r  

e m a i l  

u s  

a t 

info@fiveseasonsaircleaners.com. 
 

 

TECHNICAL DATA 

PROBLEM 

CAUSE 

Fan does not operate 
Performance Light off 

Unit not plugged in 
Cell access door not closed 
tightly 
System switch not 

ON

 

Fan does not operate 
Performance Light on 

Speed selector switch not 
positioned correctly 
Fan motor malfunction 

Fan operating  
Performance Light off 

Cell wet from washing 
Short in cell (see below) 

Cell arcing excessively 

Cell wet from washing 
Cell plate(s) bent 
Cell dirty or large lint ball/hair 
caught in cell 
Broken ionizing wire 

Dimensions 

Length 

Width 

Height 

 

13.5 in 
12.0 in 
27.3 in 

 

34.3 cm 
30.5 cm 
69.3 cm 

Weight 

40.0 lbs 

18.0 kg 

Input Voltage 

120 V   60 Hz 

220 V        60 Hz 
220-240 V 50 Hz 

Power 
Consumption 
(maximum) 

 

150 Watts 

 

Air Flow 

High 

Medium 

Low 

 

258 cfm 
200 cfm 
150 cfm 

 

439 m³/hr 
340 m³/hr 
255 m³/hr 

Cell Output Voltage  6200 VDC @ < 1 mA 

 

Collecting Cell 
Surface 

1190 in² 

7676 cm² 

Negative Ionizer 

-5000 VDC @ <.1 mA 

 

Negative Ion 
Output 

327.7 K/in³ 

20 K/cm³ 

Ideal for rooms up 
to:  (for over 3 air 
changes/hour) 

23 x 28 x 8 ft 

644 ft² 

7.0 x 8.5 x 2.5 m 

59.0 m² 

Summary of Contents for 790AI

Page 1: ...ctronically removes dust mites pollen pet dander mold bacteria viruses tobacco smoke cooking smoke and grease and more down to 0 01 micron Activated Carbon Filter removes unpleasant odors Negative Ionizer restores the air s natural ion balance 3 Speed Fan and Performance Indicator Light Ideal for rooms up to 23 x 28 x 8 ft 7 0 x 8 5 x 2 5 m with over 3 air changes per hour ...

Page 2: ...transport the unit 3 Remove all packaging from the unit Choose a suitable location to allow unobstructed circulation from front top and back of unit The unit performs best when the back is against a wall This enhances air circulation Allow at least one inch 2 5 cm away from back wall 4 Operate Air Cleaner at voltage shown on back of unit 5 The controls for the Air Cleaner are located under the hin...

Page 3: ... or ionizing wires Never place the cell in an oven to dry The edges of the cell may be sharp handle with care DAX Detergent and Carbon Filters are available from your Dealer TROUBLESHOOTING CHART The Performance Indicator Light is also used as the high voltage fault indicator If the fan is operating but the light does not come on then there is a problem in the high voltage circuit To determine the...

Page 4: ...Air Cleaner on soft surfaces i e beds sofas 12 Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type o...

Reviews: