background image

BENEFITS 

Helps  provide  relief  from  allergy,  asthma  and  other 
respiratory illness. 
Helps  clear  a  smoky  environment  quickly,  so  everyone 
can work and relax together. 
Helps reduce the time and money spent on cleaning and 
redecorating.    Prevents  damaging  black  dust  from 
staining walls, upholstery and window coverings. 
Improves  indoor  air  quality  for  a  fresher,  more 
comfortable environment, year-round. 

 

HOW IT WORKS 

Dirty air is drawn in through the front grill and passes through 
a 4-Stage filtering system. 
 
The  Electrostatic  Prefilter is  constructed  of  a  close  knit  poly 
mesh.  It prevents larger particles from entering the collecting 
cell. 
 
The next step is a 2-Stage Electrostatic Collecting Cell.  The 
dirt  particles  are  charged  with  a  high  positive  voltage  by  a 
series of fine ionizing wires.  The charged particles are drawn 
through to the collecting plates where the dirt adheres to the 
grounded  plates  and  remains  until  the  cell  is  taken  out  and 
washed. Removes particles down to .01 micron (1/2,540,000 
of an inch). 
 
The  air  is  then  drawn  through  an  Activated  Carbon/ 
Potassium Permanganate VOC (Volatile Organic Compound) 
Filter for removal of odours and gases emitted from carpets, 
cabinets,  glues,  household  cleaners,  paints,  varnishes, 
solvents,  personal  care  products,  tobacco  and  cooking 
smoke, and lots more.  Clean air is then discharged out the 
top and back of the Air Cleaner. 
 
A series of Negative Ionizer needles, controlled by a separate 
switch, are located in the clean air stream.  Adding negative 
ions  to  the  air  revitalizes  the  air  similar  to  that  near  a 
waterfall,  spring,  ocean,  or  after  a  rainfall.    Studies  have 
shown that negative ions have a beneficial effect on human 
biochemistry, both physically and mentally. 

 

OPERATING INSTRUCTIONS 

1.  Lean  Air  Cleaner  on  side  panel  and  pull  out  of  box.    If 

your unit has any signs of damage, immediately contact 
the store where the Air Cleaner was purchased. 

2.  Keep  the  shipping  carton  and  packaging  in  case  the 

need arises to store or transport the unit. 

3. 

Casters  are  packaged  inside  the  Air  Cleaner.

  Open 

access door, remove prefilter and collecting cell, remove 
casters, and install casters on bottom of unit. 

4.  Remove all packaging from the unit.  Choose a suitable 

location to allow unobstructed circulation from front, top 
and back of unit.  The unit performs best when the back 
is against a wall.  This enhances air circulation.  Allow at 
least  one  inch  (2.5  cm)  away  from  back  wall. 

Note:  Do not place Air Cleaner in direct sunlight.

 

5.  Operate Air Cleaner at voltage shown on back of unit. 

6.  The controls for the Air Cleaner are located on the front 

panel.    To  turn  the  Air  Cleaner  on,  push  the  System 
Switch to the 

ON

 position.  This controls the power to the 

Fan  Speed  Switch  and  to  the  power  board.    When  the 
Fan Speed Switch is in the extreme left position, the fan 
is on low; center position is medium; and to the right is 
high speed.  When the System Switch is turned 

ON

, the 

green Performance Indicator Light should be illuminated. 

7.  The  rocker  switch  located  under  the  red  LED,  controls 

the negative ion emitter.  When the switch is on, the red 
light will illuminate. 

 

Note:  The Negative Ion Emitter will not work without 
the System Switch being ON.

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

You  may  notice  a  slight  heat  odour  when  new  unit  is  first 
turned on.  This is normal and will disappear within a 24 hour 
period. 
We  recommend  the  Air  Cleaner  be  run  on  low  or  medium 
speed  for quiet, continuous or  nighttime  use.   Use  the  high 
speed for initial cleaning of heavy concentrations of dirty air 
(i.e. smoke) or after leaving the room. 

You may notice arcing or snapping from the cell.  It is normal 
to hear some arcing when the unit is new or first turned on.  
Arcing in the cell may also be caused by high humidity (over 
80%), after washing, or when a large particle of dirt or hair is 
caught in the cell.  If the arcing is continuous and constant, 
then refer to the Troubleshooting Chart.

 

1 Dirty Air 
 
 
2 Prefilter 
 
 
3 Charging 
   Section 

4 Collecting Cell 
   Plates 
 
5 Odour & Gas 
   Filter 
 
7 Negative Ions 
   and Clean Air 
 
6 Ionizing Needles 

OFF       ON 

Low Speed       Medium Speed       High Speed 

System Switch       Fan Speed Switch        Negative Ion Switch 

* Grey foam side must face up. 

Odour & Gas (VOC) Filter * 

 

Collecting Cell 

 

Red Fiberboard Contact 

 

Air Flow Direction Arrow 

 

Electrostatic Prefilter 

 

Access Door 

Summary of Contents for 985AIV

Page 1: ...nder mold bacteria viruses tobacco smoke cooking smoke and grease and more down to 01 micron Odour Gas VOC Volatile Organic Compound Filter removes noxious odours and gases optional Triple Negative Ionizer restores the air s natural ion balance Quiet 3 Speed Fan and Performance Indicator Light Mobile easily moves from room to room Ideal for rooms up to 28 x 30 x 8 ft 8 5 x 9 1 x 2 5 m with over 3 ...

Page 2: ...de the Air Cleaner Open access door remove prefilter and collecting cell remove casters and install casters on bottom of unit 4 Remove all packaging from the unit Choose a suitable location to allow unobstructed circulation from front top and back of unit The unit performs best when the back is against a wall This enhances air circulation Allow at least one inch 2 5 cm away from back wall Note Do ...

Page 3: ...X Detergent and the Odour Gas VOC Filter are available from your Dealer TROUBLESHOOTING CHART The two operation lights are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine the problem turn the Air Cleaner OFF and remove the collecting cell Close the access door and turn the Air Clean...

Page 4: ...urfaces i e beds sofas 12 Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source indica...