5.  A duct adapter and a length of 6 inch flexible hose 

or  duct  is  required  to  attach  between  the  exhaust 
collar and the existing cold air return. The exhaust 
hose  should  be  attached  to  the  return  air  duct, 
close  to  the  furnace.  The  ideal  location  is  low  on 
the  return  air  boot  pointing  at  the  furnace.  To 
prevent  air  shear  inside  the  duct,  it  is 
recommended that you install a deflector inside the 
boot,  so  the  discharged  air  is  deflected  down  into 
the  boot.  When  running  the  hose,  make  sure  that 
there are no kinks or sharp bends that will impede 
the  air  flow  from  the  unit.    Secure  and  seal  the 
hose and connections to prevent air leakage. 

6.  It  is  important  to  maintain  some  distance  between 

the  intake  and  the  exhaust  openings  in  the  return 
air  duct.  Failure  to  do  this  may  result  in  short 
cycling  between  the  intake  and  the  clean  air 
discharge.  It  is  recommended  you  leave  10  feet 
between  the  intake  and  the  exhaust;  however,  as 
little as 6 feet will work effectively. If the distance is 
smaller  than  6  feet,  it  is  important  that  an  air 
deflector is installed in the duct. 

7.  If  outside  air  is  introduced  into  the  return  air  duct, 

either through a HRV (Heat Recovery Ventilator) or 
direct, it should be added to the system before the 
intake inlet to the Air Cleaner.  

OPERATING INSTRUCTIONS

 

The HEPA Air Cleaner is designed to run continuously 
to provide clean, filtered air 24 hours a day. The fan on 
the  heating/cooling  system,  to  which  the  HEPA  Air 
Cleaner  is  dependent  on  for  circulated  air,  should  be 
on ‘continuous’. 

Note:   

If the system fan setting is on  ‘automatic’,  it is 

recommended  the  HEPA  Air  Cleaner  be  operated 
through  an  air  switch  or  relay  to  turn  the  Air  Cleaner 
off, when there is no system fan on. 

The  unit  plugs  into  a  regular  120  volt  outlet  and  is 
controlled  by  a  switch  located  on  the  rear  panel,  near 
the cord. 

Note:

  Do not allow the cord to be placed where it may 

be walked on or allow anything to roll over it. 

The  top  cover  must  be  secured  for  the  Air  Cleaner  to 
operate.    All  filters  must  be  in  place  for  the  unit  to 
operate properly. 

 

MAINTENANCE

 

For efficient operation, the filters must be changed on a 
regular basis. If you notice a reduction in air flow from 
the system, check the filters.  

1.  To  access  the  filters,  turn  the  Air  Cleaner 

OFF

  at 

the switch and remove the top cover. 

2.  Release  the  filter  hold  down  bar  by  pulling  it 

forward one side at a time. 

3.  Carefully remove filters to avoid spilling of collected 

contaminants.  Dispose  of  filters  in  a  plastic  bag 
and discard with regular household trash. 

4.  Remove  plastic  from  new  filters  before  installing. 

Discard plastic safely. Take care not to damage the 
filters. 

5.  Date the replacement filter in the space provided. 
6.  Place  the  Carbon  prefilter  around  the  HEPA  filter 

and secure with the Velcro. 

7.  Ensure  the  open  end  of  the  HEPA  filter  is  toward 

the motor. 

8.  Replace  the  filter  hold  down  bar  by  placing  one 

side  under  the  bracket  on  the  side  of  the  cabinet.  
Once  you  have  one  side  started,  force  the  bar 
under the bracket on the other side of the cabinet.  
This ensures the filter has a good seal. 

9.  Use  genuine  replacement  filters  only.  Call  the 

original installer for parts. 

Note:

  When the filters are new, you may notice a new 

smell from the system. This is normal and will dissipate 
within a few days. 

Carbon  Prefilter  (Part  #W3-0855):

    This  must  be 

replaced  every  3  -  6  months  and  may  be  vacuumed 
between  changes.  Use  a  soft  brush  attachment  when 
cleaning.    If  there  are  heavy  odors  in  the  home  from 
cooking,  smoking,  painting  or  other  sources,  the  filter 
will require changing more often. 

True HEPA Filter (Part #W3-0840):

  Replace every 2-

3 years. The life of this filter depends on the amount of 
contaminants in the air and the frequency in which the 
prefilter  has  been  changed.  Renovations  in  the  home 
that create  wood,  drywall  dust or similar contaminants 
will  shorten  the  life  expectancy  of  the  HEPA  filter.  To 
improve  airflow,  the  HEPA  filter  can  be  vacuumed 
between  changes,  preferably  outdoors.  Use  a  soft 
brush attachment for vacuuming this filter. 

Note:

    Handle  the  HEPA  filter  by  the  frame  only.  The 

paper  is  fragile  and  a  puncture  or  tear  will  reduce 
efficiency. 

VOC After Filter (Part #W3-0810 optional):

  This filter 

is  positioned  inside  the  HEPA  filter,  and  must  be 
replaced  every  6-12  months.  If  there  are  heavy  odors 
in  the  home  from  cooking,  smoking,  painting  or  other 
sources, the filter may require changing more often. 

WARNING  

Never use the unit without all of the filters in place.  

CAUTION  

Make  sure  to  turn  Air  Cleaner 

OFF

  before 

performing  any  maintenance  or  removing  any 
components.  

Summary of Contents for FSHEPA350

Page 1: ...on Prefilter removes lint and unpleasant odors to extend life of HEPA Filter Carbon VOC After Filter removes additional unpleasant odors and gases optional Easy to change filters Heavy gauge steel cabinet and powder coat paint finish provide rigid installation and durability Powerful motor delivers 245 CFM of filtered air Small footprint for easier more convenient installation Versatile installati...

Page 2: ...ulate Air Filter which captures 99 97 of particles 0 3 micron 1 84 000 of an inch and larger This HEPA filter has more than 65 ft of collection surface area Clean air is discharged through a 6 inch duct back into the return air duct INSTALLATION LOCATION The HEPA Air Cleaner should be located as close to the return air duct as possible This allows for shorter lengths of ducting which helps keep th...

Page 3: ...m the system check the filters 1 To access the filters turn the Air Cleaner OFF at the switch and remove the top cover 2 Release the filter hold down bar by pulling it forward one side at a time 3 Carefully remove filters to avoid spilling of collected contaminants Dispose of filters in a plastic bag and discard with regular household trash 4 Remove plastic from new filters before installing Disca...

Page 4: ... changed by any distributor dealer or other person whatsoever FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning and or replacement of filters 2 Damage or repairs needed as a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 3 Damage or repairs requir...