SAFETY CONSIDERATIONS 

Read  and  follow  instructions  carefully.  Follow  all  local 
electrical  codes  during  installation.  All  wiring  must 
conform  to  local  and  national  electrical  codes. 
Improper wiring or installation may damage the HEPA 
Air Cleaner. 

Understand  the  signal  words 

WARNING

  and 

CAUTION

  which  are  present  in  the  Owner’s  Manual. 

WARNING 

and 

CAUTION

 signify a hazard which could 

result in property damage, personal injury or death. 

Only a heating/air conditioning installer or qualified 
service  person  should  install,  repair,  or  service 
your Whole-House HEPA Air Cleaner. 
Homeowners  or  untrained  personnel  can  perform 
the  basic  maintenance  functions  of  replacing 
filters. 
When working on air cleaning equipment, observe 
precautions in the Owner’s Manual, labels attached 
to  the  unit,  and  other  safety  precautions  that  may 
apply. Follow all safety codes. Wear safety glasses 
and work gloves. 

WHAT THE HEPA AIR CLEANER DOES 

The  Whole-House  HEPA  Air  Cleaner  has  been 
designed  to  remove  particulate  such  as  atmospheric 
and household dust, coal dust, insecticide dust, mites, 
pollen,  mold  spores,  fungi,  bacteria,  viruses,  pet 
dander,  cooking  smoke  and  grease,  tobacco  smoke 
and  more.  It  also  removes  odors  with  the  Carbon 
Prefilter. 

BENEFITS 

Helps  provide  relief  from  allergies,  asthma,  and 
other respiratory illness. 
Helps reduce housekeeping time and redecorating 
costs. 
Provides  a  healthier,  more  comfortable 
environment, year-round. 

HOW IT WORKS 

Millions  of  airborne  pollutants  are  carried  through  the 
return  air  ducts  of  the  heating/cooling  system.  The 
HEPA Air Cleaner has been designed to be ducted to 
the  return  air  duct.    A  portion  of  this  return  air  is  by-
passed through an 8 inch intake duct on the top of the 
unit and passes through a 2-stage filtration system. 
The  Activated  Carbon  Prefilter  (activated  carbon 
impregnated  polyester  filter)  first  removes  lint  and 
odors before they enter the HEPA filter. 
Smaller  particles  then  pass  through  a  long-life,  HEPA 
(High  Efficiency  Particulate  Air)  Filter  which  captures 
99.97%  of  particles  0.3  micron  (1/84,000  of  an  inch) 
and  larger.  This  HEPA  filter  has  more  than  100  ft²  of 

collection surface area. 
Clean air is discharged through a 6 inch duct, back into 
the return air duct. 

INSTALLATION 

 
 
 
 
 
 
 
 
 
 
 
 

LOCATION 

The  HEPA  Air  Cleaner  should  be  located  as  close  to 
the return air duct  as possible. This allows for shorter 
lengths of ducting which helps keep the static pressure 
lower.  The unit can be adapted to mount on a wall or 
be  suspended  from  the  ceiling.  Care  should  be  taken 
to  keep  the  unit  away  from  an  area  where  there  is  a 
possibility of moisture leaking on to it. Ensure there is 
36  inches  in  front  of  the  unit  to  remove  the  filters  for 
cleaning or replacing. 

NOTE:

  If the unit is going to be mounted on it’s back 

you  must  contact  the  distributor  for  special  mounting 
kit.

 

GENERAL INSTALLATION STEPS 

1.  Remove  any  packaging  or  plastic  from  filters 

before installing. See  Maintenance for instructions 
to remove the filters. 

2.  When  the  unit  is  shipped,  the  intake  and  exhaust 

collars are reverse mounted to prevent damage in 
shipping.  The  intake  collar  must  be  removed  and 
reattached  with  the  collar  ring  facing  out.  The 
exhaust  collar  can  be  mounted  on  one  of  three 
sides  of  the  unit  with  the  ring  out.  The  other  two 
sides  will  be  covered  with  the  exhaust  covers. 

These  covers  must  be  installed  for  the  unit  to 
operate properly.

 

3.  An  inlet  collar  is  provided  on  the  unit  to  allow  a  

flexible 8 inch intake duct, from the cold air return, 
to  be  attached.  The  8  inch  intake  must  be  drawn 
from  the  cold  air  return  duct  at  a  location  that  will 
be  ahead  of  the  clean  exhaust  air,  that  will  be 
returned to the duct from the Air Cleaner. 

WARNING  

Before  beginning  any  installation  or  modification,  be 
certain  that  the  main  line  electrical  disconnect  switch 
is in the 

OFF

 position. Electric shock could result. Tag 

disconnect switch with suitable warning labels.  

WARNING  

This  unit  must  be  installed  on  the  return  air  side  of 
the system only. Do not connect to supply side. 
Do not install in a cooking area or connect directly to 
any appliance.  

HEPA 

UNIT 

 

HEATING 

COOLING 

SYSTEM 

RETURN AIR 

SUPPLY AIR 

DEFLECTOR 

AIR CLEANER 

Summary of Contents for FSHEPA450

Page 1: ...ves lint and unpleasant odors to extend life of HEPA Filter Carbon VOC After Filter removes additional unpleasant odors and gases optional Easy to change filters Heavy gauge steel cabinet and powder coat paint finish provide rigid installation and durability Powerful motor delivers 330 CFM of filtered air Small footprint for easier more convenient installation Three air outlets for versatility Ver...

Page 2: ... Particulate Air Filter which captures 99 97 of particles 0 3 micron 1 84 000 of an inch and larger This HEPA filter has more than 100 ft of collection surface area Clean air is discharged through a 6 inch duct back into the return air duct INSTALLATION LOCATION The HEPA Air Cleaner should be located as close to the return air duct as possible This allows for shorter lengths of ducting which helps...

Page 3: ...r Cleaner to operate All filters must be in place for the unit to operate properly MAINTENANCE For efficient operation the filters must be changed on a regular basis If you notice a reduction in air flow from the system check the filters 1 To access the filters turn the Air Cleaner OFF at the switch and remove the front door 2 Release the filter hold down bar by pulling it forward one side at a ti...

Page 4: ...anged by any distributor dealer or other person whatsoever FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning and or replacement of filters 2 Damage or repairs needed as a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 3 Damage or repairs required ...

Reviews: