background image

CONTENTS 

SAFETY CONSIDERATIONS                                           2 
WHAT THE ELECTRONIC AIR CLEANER DOES           2 
BENEFITS                                                                         2 
HOW IT WORKS                                                               2 
MAJOR COMPONENTS                                                   3 
INSTALLATION                                                              3-4 
Mounting                                                                            3 
OPERATION & MAINTENANCE                                       4 
Wiring                                                                                4 
Operation Check                                                               4 
Maintenance Schedule                                                      4 
Cleaning and Service                                                        4 
Service Maintenance                                                        4 
SERVICE                                                                           5 
TROUBLESHOOTING GUIDE                                          5 
Electrical Schematic - 120 V                                             6 
Electrical Schematic With Wired Remote - 120 V             6 
Electrical Schematic - 220 V                                             7 
Electrical Schematic With Wired Remote - 220 V             7 
Exploded View                                                                   8 
WARRANTY                                                                      8 

SAFETY CONSIDERATIONS 

Read  and  follow  instructions  carefully.  Follow  all  local 
electrical  codes  during  installation.  All  wiring  must 
conform  to  local  and  national  electrical  codes.  Improper 
wiring or installation may damage Air Cleaner. 

Understand  the  signal  words  WARNING  and  CAUTION 
which are present in the Installation, Operation & Service 
Instructions. 

WARNING and CAUTION signifies a hazard which could 
result in property damage, personal injury or death. 

Installation  and  servicing  of  Electronic  Air  Cleaners 
can  be  hazardous.  Only  trained  and  qualified  service 
personnel should install, repair, or service Electronic 
Air Cleaners. 
Untrained  personnel  can  perform  the  basic 
maintenance  functions  of  cleaning  and  replacing 
filters. 
When  working  on  air  cleaning  equipment,  observe 
precautions in the manual, labels attached to the unit, 
and  other  safety  precautions  that  may  apply.  Follow 
all  safety  codes.  Wear  safety  glasses  and  work 
gloves. 

 
 

WHAT THE ELECTRONIC AIR CLEANER DOES 

Your  High  Efficiency  Electronic  Air  Cleaner  has  been 
designed  to  remove  tobacco  smoke  particles,  cooking 
smoke  and  grease,  atmospheric  dust,  coal  dust, 
insecticide  dust,  mites,  pollen,  mold  spores,  fungi, 
bacteria,  viruses  and  more  down  to  0.01  micron  (0.01 
micron = 1/2,540,000 of an inch). 

BENEFITS 

Helps  clear  up  a  smokey  environment  quickly,  so 
customers can dine more comfortably. 
Helps employees reduce suffering from irritated eyes, 
nasal  congestion  and  respiratory  problems  that  lead 
to absenteeism. 
Helps  prevent  damaging  black  and  greasy  particles 
from staining ceilings, walls and furnishings, reducing 
the amount of housekeeping and redecorating costs. 
Helps to lower energy bills by recycling air rather than 
exhausting expensive heated or cooled air. 

 

HOW IT WORKS 

The  Electronic  Air  Cleaner  operates  on  the  principle  of 
“Electrostatic Precipitation.”  Millions of airborne pollutants 
are drawn through the intake grill on the bottom of the Air 
Cleaner  and  first  pass  through  a  prefilter  which  removes 
all  large  visible  particles,  such  as  lint.    Next,  smaller 
particles  move  to  a  2-stage  electrostatic  collecting  cell 
where  they  are  given  a  powerful  positive  charge  by  the 
ionizing  wires.    Charged  particles  then  move  into  the 
collecting  area  where  they  are  attracted  to  a  series  of 
grounded plates.  Pollutants are held in this section like a 
magnet  until  washed  away  during  cleaning.    Clean  air  is 
then  dispersed  from  the  side  grills  in  four  directions 
allowing superior air flow circulation. 

 

 
 
 
 
 
 
 
 
 
 
 
 

The  Air  Cleaner 
creates a circular 
air  flow  pattern 
wh ic h 

ne v er 

allows air to short
-cycle  or  rest  at 
the ceiling. 

3 - Stage Electronic 
Air Cleaning Process:

 

1 - Prefilter Screen 
2 - Charging Section 
3 - Grounded Plates 

1       2      3      

Electrostatic Precipitation 

IMPORTANT:

  Please read entire instructions before 

installing the Electronic Air Cleaner. 

WARNING  

Before  beginning  any  installation  or  modification,  be 
certain that the main line electrical disconnect switch is 
in 

OFF

  position.  Electric  shock  could  result.  Tag 

disconnect switch with suitable warning labels.  

Coanda Air Flow 

Summary of Contents for SSC-7

Page 1: ...Operation And Maintenance Manual MODEL SSC 7 SEMI FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Page 2: ...gi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employees reduce suffering from irritated eyes nasal congestion and respiratory problems that lead to absenteeism Helps prevent damaging black and greasy particles from staining ceilings walls and furnishings reducing ...

Page 3: ...e ionizing section is charged at approximately 7500 VDC The collecting plates are alternately grounded and charged at 5000 VDC The arrow on the cells indicates the direction of air flow which must point up towards the fan motor MOTOR AND FAN BLADE The motor is 1 33 HP 1050 RPM 3 speed controlled by a 3 position slide switch The motor is thermally protected The fan blade is 14 in 35 5 cm with a 20o...

Page 4: ...ell well with hot water 120ºF 49ºC maximum 5 If dirt or nicotine remains on plates let cell soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or misalign cell plates 6 Spray prefilter with DAX Detergent and rinse well 7 To dry cell tilt on 45º angle against wall with arrow pointing sideways Allow to dry completely for at least 8...

Page 5: ...ker is ON or voltage is supplied to unit 2 Main supply fuse or breaker is not tripped 3 Unit cover is completely closed and locked into place 4 System switch is ON Performance Indicator Light OFF 1 System switch is ON 2 Remove cell close access door and turn unit ON If Performance Indicator is still off problem is in the power box If light comes on with no cell then there is a short circuit in the...

Page 6: ...Electrical Schematic A 120 Volt Electrical Schematic B with Wireless Remote 120 Volt ...

Page 7: ...Electrical Schematic A 220 240 Volt Electrical Schematic B with Wireless Remote 220 240 Volt ...

Page 8: ...a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the control ...

Reviews: