background image

Five Seasons Comfort Limited 

351 North Rivermede Road, Concord, Ontario, Canada  L4K 3N2 

Toll Free:  1-800-267-8305          Phone:  (416) 213-5636          Fax:  (416) 213-5593 

Email:  info@fiveseasonsaircleaners.com     Web:  www.fiveseasonsaircleaners.com 

ssc7.pub 

03/12 

LIMITED ONE YEAR WARRANTY 

Your  Electronic  Air  Cleaner  is  guaranteed  for  one  (1)  year  from  the  date  of  original  purchase,  against  electrical  and 
mechanical defects in material and workmanship, under normal use and maintenance, which will be repaired or replaced 
without charge, upon inspection by an authorized service center.  The warranty does not include the prefilter.  
This guarantee is in lieu of any other warranty, either expressed or implied. 
FIVE SEASONS COMFORT LIMITED will not be responsible for: 
1.  Normal maintenance as outlined in the Operation & Maintenance Manual including cleaning of electronic collecting 

cells. 

2.  Damage or repairs required as a consequence of faulty installation or application by others. 
3.  Damage  or  repairs  needed  as  a  consequence  of  any  misapplication,  negligent  handling,  improper  servicing, 

unauthorized alteration, or improper operations. 

4.  Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy 

or interruption of electrical service. 

5.  Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond the 

control of FIVE SEASONS COMFORT LIMITED. 

6.  Parts not supplied or designated by FIVE SEASONS COMFORT LIMITED. 
7.  FIVE  SEASONS  COMFORT  LIMITED  products  installed  outside  the  continental  Canada,  U.S.A.,  Alaska,  and 

Hawaii. 

8.  Any personal injury, special indirect or consequential property or commercial damage of any nature whatsoever. 
If warranty service is required, send the part(s) prepaid to your dealer or nearest authorized service center, with a 

proof 

of  purchase

.    Ensure  that  sufficient  packing  material  is  used.    If  part(s)  arrive  damaged  due  to  improper  packaging, 

warranty will be void.  Please enclose a note explaining the nature of your difficulty. 

 

Model No. 

 

 

 

 

 

Serial No. 

 

Date of Purchase 

 

 

 

 

Dealer Name 

 

Owner‟s Company Name & Address 

RETAIN THIS CERTIFICATE WITH YOUR VALUABLE DOCUMENTS 

Exploded View

 

Summary of Contents for SSC-7

Page 1: ...Operation And Maintenance Manual MODEL SSC 7 SEMI FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Page 2: ...gi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employees reduce suffering from irritated eyes nasal congestion and respiratory problems that lead to absenteeism Helps prevent damaging black and greasy particles from staining ceilings walls and furnishings reducing ...

Page 3: ...e ionizing section is charged at approximately 7500 VDC The collecting plates are alternately grounded and charged at 5000 VDC The arrow on the cells indicates the direction of air flow which must point up towards the fan motor MOTOR AND FAN BLADE The motor is 1 33 HP 1050 RPM 3 speed controlled by a 3 position slide switch The motor is thermally protected The fan blade is 14 in 35 5 cm with a 20o...

Page 4: ...ell well with hot water 120ºF 49ºC maximum 5 If dirt or nicotine remains on plates let cell soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or misalign cell plates 6 Spray prefilter with DAX Detergent and rinse well 7 To dry cell tilt on 45º angle against wall with arrow pointing sideways Allow to dry completely for at least 8...

Page 5: ...ker is ON or voltage is supplied to unit 2 Main supply fuse or breaker is not tripped 3 Unit cover is completely closed and locked into place 4 System switch is ON Performance Indicator Light OFF 1 System switch is ON 2 Remove cell close access door and turn unit ON If Performance Indicator is still off problem is in the power box If light comes on with no cell then there is a short circuit in the...

Page 6: ...Electrical Schematic A 120 Volt Electrical Schematic B with Wireless Remote 120 Volt ...

Page 7: ...Electrical Schematic A 220 240 Volt Electrical Schematic B with Wireless Remote 220 240 Volt ...

Page 8: ...a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the control ...