background image

CONTENTS 

SAFETY CONSIDERATIONS                                      2 
WHAT THE ELECTRONIC AIR CLEANER DOES       2 
BENEFITS                                                                    2 
HOW IT WORKS                                                          2 
MAJOR COMPONENTS                                              3 
INSTALLATION                                                         3-4 
Mounting                                                                       3 
OPERATION & MAINTENANCE                                  4 
Wiring                                                                            4 
Operation Check                                                           4 
Maintenance Schedule                                                 4 
Cleaning and Service                                                    4 
Service Maintenance                                                    4 
SERVICE                                                                      5 
TROUBLESHOOTING GUIDE                                     5 
Electrical Schematic - 120 V                                         6 
Electrical Schematic With Wired Remote - 120 V         6 
Electrical Schematic - 220 V                                         7 
Electrical Schematic With Wired Remote - 220 V         7 
Exploded View                                                              8 
WARRANTY                                                                 8 

SAFETY CONSIDERATIONS 

Read  and  follow  instructions  carefully.  Follow  all  local 
electrical  codes  during  installation.  All  wiring  must 
conform to local and national electrical codes. Improper 
wiring or installation may damage Air Cleaner. 

Understand the signal words WARNING and CAUTION 
which  are  present  in  the  Installation,  Operation  & 
Service Instructions. 

WARNING  and  CAUTION  signifies  a  hazard  which 
could  result  in  property  damage,  personal  injury  or 
death. 

Installation and servicing of Electronic Air Cleaners 
can  be  hazardous.  Only  trained  and  qualified 
service  personnel  should  install,  repair,  or  service 
Electronic Air Cleaners. 
Untrained  personnel  can  perform  the  basic 
maintenance  functions  of  cleaning  and  replacing 
filters. 
When working on air  cleaning equipment, observe 
precautions  in  the  manual,  labels  attached  to  the 
unit,  and  other  safety  precautions  that  may  apply. 
Follow  all  safety  codes.  Wear  safety  glasses  and 
work gloves. 

 

WHAT THE ELECTRONIC AIR CLEANER DOES 

Your  High  Efficiency  Electronic  Air  Cleaner  has  been 
designed  to  remove  tobacco  smoke  particles,  cooking 
smoke  and  grease,  atmospheric  dust,  coal  dust, 
insecticide  dust,  mites,  pollen,  mold  spores,  fungi, 
bacteria,  viruses  and  more  down  to  0.01  micron  (0.01 
micron = 1/2,540,000 of an inch). 

BENEFITS 

Helps  clear  up  a  smokey  environment  quickly,  so 
customers can dine more comfortably. 
Helps  employees  reduce  suffering  from  irritated 
eyes,  nasal  congestion  and  respiratory  problems 
that lead to absenteeism. 
Helps prevent damaging black and greasy particles 
from  staining  ceilings,  walls  and  furnishings, 
reducing  the  amount  of  housekeeping  and 
redecorating costs. 
Helps  to  lower  energy  bills  by  recycling  air  rather 
than exhausting expensive heated or cooled air. 

HOW IT WORKS

 

This Air Cleaner works on the principle of "Electrostatic 
Precipitation".  Millions of airborne pollutants are drawn 
through the intake grill on the bottom of the Air Cleaner 
and  first  pass  through  a  Prefilter  which  removes  all 
large  visible  particles  such  as  lint.    Next,  smaller 
particles  move  to  a  two-stage  electrostatic  Collecting 
Cell where they are given a powerful positive charge by 
the  ionizing  wires.    Charged  particles  then  move  into 
the collecting area where they are attracted to a series 
of grounded plates.  Pollutants are held in this section 
like  a  magnet  until  washed  away  during  cleaning.  
Clean  air  is  then  dispersed  from  the  side  grills  in  four 
directions allowing superior air flow circulation. 

 
 

 
 
 
 
 
 
 
 

 
 

 

 
The  Air  Cleaner 
creates  a  circular 
air  flow  pattern 
which  never allows 
air  to  rest  at  the 
ceiling. 

IMPORTANT:

  Please read entire instructions before 

installing the Electronic Air Cleaner. 

WARNING  

Before  beginning  any  installation  or  modification,  be 
certain  that  the  main  line  electrical  disconnect  switch 
is  in 

OFF

  position.  Electric  shock  could  result.  Tag 

disconnect switch with suitable warning labels.  

3 - Stage Electronic Air 

Cleaning Process:

 

1 - Prefilter Screen 
2 - Charging Section 
3 - Grounded Plates 

1       2      3      

Electrostatic Precipitation 

Coanda Air Flow 

Summary of Contents for SSCB15

Page 1: ...Operation And Maintenance Manual MODEL SSCB15 CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Page 2: ...ld spores fungi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employees reduce suffering from irritated eyes nasal congestion and respiratory problems that lead to absenteeism Helps prevent damaging black and greasy particles from staining ceilings walls and furnishi...

Page 3: ...TALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be done by a knowledgeable technician 4 After installation check out operation as provided in these instructions Mounting 1 Remove the unit from the box with packing still on the unit and lay it on its back grill side up 2 Rele...

Page 4: ...otine remains on plates let Cells soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or bend cell plates 5 Spray Prefilters with DAX Detergent and rinse well 6 To dry cells tilt on 45º angle against wall with arrows pointing sideways Allow to dry completely for 10 24 hours Place in sunlight for faster drying time 7 When the Cells...

Page 5: ...3 Unit cover is completely closed and locked into place 4 Power switch is ON Performance Indicator Light Is Not Lit 1 System switch is ON 2 Remove Cells close access door and turn unit ON If Performance Indicator is still off problem is in the power box If light comes on with no cells then there is a short circuit in the cells Place one cell in the unit close access door and turn unit ON If the li...

Page 6: ...Electrical Schematic B with Wired Remote 120 Volt Electrical Schematic A 120 Volt ...

Page 7: ...Electrical Schematic B with Wired Remote 220 240 Volt Electrical Schematic A 220 240 Volt ...

Page 8: ...s a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the contro...