34 / 58
7
Registers management
Memory Organization
The user must know that a new register value sent through the
communication port is loaded to the running parameters in RAM and used
for the current process. All these parameters are lost upon power-down. It
is required to save them to “User Parameters” or “Factory Parameters” with
the corresponding function.
NON VOLATI
LE D
A
TA.
EEPROM
EEPROM
ROM
USER
Parameters
Saved
FACTORY
Parameters
Saved
SOS IP
address
5
1
2
3
4
VOLATI
LE DATA.
RAM
RUNNING
WR
IT
E
Parameters
RE
AD
PROCESSES
Communication port
(TCP/UDP)
[Web page or Software]
Action Number and description:
1
SaveUserParameters
(0x03) function
During standard power-up or calling
2
RestoreUserParameters
(0x04) function
3
RestoreFactoryParameters
(0x05) function
SaveFactoryParameters
(0x06) function
+
1
4
[For integrators engineers only]
5
By setting “SOS Jumper” after power-up
3
5
+ +
1
By setting “SOS Jumper” during power-up
FMod-TCP User Manual v.2.8