STEP 15

 

 

CHECKLIST FOR OPEN BURNER INSTALLATION 

 

 

MAKE SURE ALL CONTROLS ARE IN THE “OFF” POSITION.

 

 

 

Gas supply is “on” 

 

 

Electric power is “on” 

 

 

Burner drip pans in position under burners 

 

 

Surface burners in position 

 

 

Burner pans in positions 

 

 

Burner grates in position 

 

 

Oven and broiler racks installed 

 

 

Surface burner ignition test 

 

 

Gas oven ignition test 

 

 

MAKE SURE ALL CONTROLS ARE LEFT IN THE “OFF” POSITION

 

 
 
 
 
Date Installed & Inspected __________________________________________________ 

 

Authorized Installer’s Signature  _____________________________________________ 

 

Please Print Name  ________________________________________________________ 
 

 

NOTE: Please leave this checklist, Use & Care manual and product registration 
card with the Homeowner.

 

 

Summary of Contents for PN480-7BW

Page 1: ...BURNERS 24 NATURAL GAS MODEL TN480 7BW THESE MODELS ARE FIELD CONVERITBLE FOR LP PROPANE GAS 24 LP PROPANE GAS MODEL PN480 7BW THESE MODELS ARE FIELD CONVERTIBLE FOR NATURAL GAS IF YOU HAVE QUESTIONS CALL 800 251 7224 8 AM TO 5 PM EASTERN TIME OR VISIT OUR WEBSITE WWW FIVESTARRANGE COM ...

Page 2: ...hod of gas range installation Local codes vary Installation electrical FiveStar recommends this product be installed by a connections and grounding must comply with applicable licensed professional codes In the absence of local codes the gas range should be installed in accordance with the National Fuel Gas Code Product failure due to improper installation is not ANSI 223 1 latest edition and Nati...

Page 3: ...eight claim Do not refuse shipment Responsibility for shipping damage is with the carrier and the dealer or end user Cut the shipping straps then carefully lift the carton up from the range This will help eliminate possible damage to the backguard that is packed in the top of the range carton Remove unwrap and temporarily lay aside any parts that are not attached to the range Make sure no parts ar...

Page 4: ... weight of these ranges use a dolly with soft wheels to move this range Lift the range onto the dolly and move indoors The range should be placed onto sliders to prevent damage to the floor STEP 3 To simplify handling and to reduce the weight of the range Remove the grates and the burner pans Remove griddle grill and housing Remove the broiler pan racks and literature package from inside oven ...

Page 5: ... to minimize the possibility of shock hazard from this appliance If the electrical service provided does not meet the above specifications it is recommended that a licensed electrician install an approved outlet DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER CORD DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE Locate the electric supply within the area shown or...

Page 6: ......

Page 7: ...ademark of Dupont with Teflon tape all around male external pipe threads 7 1 Remove the left most burner pan Locate the pressure regulator Left of the rear burner 7 2 Install a manual gas shut off valve in the gas line in an easily accessed location outside the range Make sure everyone operating the range knows where and how to shut off the gas supply to the range 7 3 Install male flare union adap...

Page 8: ...and gas flexible tubing 3 To adjust leveling legs turn counter clockwise to raise the range clockwise to lower Channel lock type pliers are recommended Avoid using a pipe wrench which can scar the legs IMPORTANT The range should always be installed at countertop height or higher DO NOT INSTALL THE RANGE LOWER THAN ADJACENT COUNTERTOP HEIGHT DUE TO RISK OF A FIRE HAZARD ...

Page 9: ......

Page 10: ...ill continue sparking until the knob is turned from the light position First test may require some time while air is flushed out of the gas line Turn knob to OFF Repeat the procedure for each burner Burner flames should be blue and stable with no yellow or yellow tips excessive noise or lifting of the flame from the burner If any of these conditions exist check that the burner ports are not blocke...

Page 11: ... and broiler racks installed Surface burner ignition test Gas oven ignition test MAKE SURE ALL CONTROLS ARE LEFT IN THE OFF POSITION Date Installed Inspected __________________________________________________ Authorized Installer s Signature _____________________________________________ Please Print Name ________________________________________________________ NOTE Please leave this checklist Use ...