background image

 

INSTRUCTION MANUAL 

Electrical winches LM90A/LM250A

 

Réf : 1813000156 
Page : 

13/17

 

Version : 23/21 

3.2

 

Troubleshooting 

Faults 
observed 

Potential causes of the fault 

Remedies 

The 

motor 

does not rotate 

The temperature sensor is activated 
The motor has a mechanical fault 
The  contactor  in  the  hoist  is  out  of  order  or 
disconnected  
The limit switch is activated 
Fault in the control circuit  
Fault in the power circuit 
Power supply fault 
Current escape to earth 
Batteries of the remote control out-of-order 

Wait for a drop in temperature 
Check the motor 
Reconnect or replace it 

To be checked by a competent person 

Check 

The hoist does 
not lift 

The grooved pulley is worn or dirty 
The  condenser  is  disconnected  or  out  of 
order 
The temperature sensor is activated 
The motor is blocked 
The contactor on the hoist is out of order or 
disconnected 
The limit switch is activated 
Fault in the control circuit 
Fault in the power circuit 

Verification 
Verification 

Wait for a drop in temperature 
Verification (maintenance) 
Reconnect or replace it 

To be checked by a competent person 

The hoist does 
not lower 

The temperature sensor is activated 
The motor is blocked 
The  contactors  in  the  hoist  are  off  or 
disconnected 
Error in the control circuit 
Error in the power circuit 

Wait until it cools 
Check the motor 
Reconnect or change 

To be checked by a competent person 

The  motor  is 
powered 

but 

stops  (snoring 
sound) 

The  capacitor  is  disconnected  or  out  of 
service (for single phase hoist only) 
The motor is blocked 
Power cable section too thin 

Verification 

Verification (maintenance) 
Replace the power cable 

The hoist does 
not  lift  the 
load 

The groove pulley is worn or dirty 
The  capacitor  is  disconnected  or  out  of 
service (for single phase hoist only) 
The temperature sensor is activated 
Power cable section too thin 
The wire rope is inserted in wrong way 

Verification 
Verification 

Wait until it cools 
Replace the power cable 
Verification 

Current 

too 

high 

The brake is out of service 
The  capacitor  is  disconnected  or  out  of 
service (mono phase hoist only) 
The motor is blocked 

Verification 
Reconnect the capacitor or change it 

Verification (maintenance) 

Slow slide 

The groove pulley is worn or dirty 
The brake is worn 
The adhesion system is worn or dirty 

Verification 
Adjust the brake 
Verification 

3.3

 

Spare parts 

 Use only FIXATOR original spare parts. 

Note  and  send  the  information  listed  on  the  plate 
shown below before requesting parts. 

Summary of Contents for LM250A

Page 1: ...MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 1 17 Version 23 21 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 08th Jun 2021 New format type A for Radio option modif...

Page 2: ...ARNINGS ABOUT CONTRAINDICATIONS 10 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENANCE OPERATIONS 11 3 1 1 Preventive maintenance 11 3 1 2 Adjusting...

Page 3: ...r work such as in an elevator shaft or on building facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable...

Page 4: ...a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections 1 6 Recommendations for use and general safety Before using thi...

Page 5: ...r the effort to apply If the anchoring is not provided by FIXATOR each anchor must withstand without any deformation up to 2 5 times the WLL of the winch that is 2 5x90 225 kg respectively 2 5x250 625...

Page 6: ...ualified technician 2 1 1 Suspended installation It s the simplest mounting and the most common Device in suspension and direct traction or lifting The anchoring of the device must be done exclusively...

Page 7: ...ft height plus at least 1 meter of apparent slack strand The limit spring mounted on the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve...

Page 8: ...e main power plug 2 1 4 2 Commissioning Unlock the emergency stop if necessary Press the UP button to lift or pull the load Press the DOWN button to lower the load At any time in case of imminent dang...

Page 9: ...t the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installation and use...

Page 10: ...he load Avoid heavy slipping Wait for a complete stop of your installation before resuming movement Check regularly that no obstacle is located along the path of movement above and below the load 2 4...

Page 11: ...ust be reviewed at least once a year and every 100h In harsh environments sandblasting marine back and forth operation at full load doubts about the proper use etc a higher frequency of verifications...

Page 12: ...ly original FIXATOR parts ask the complete list of spare parts 3 1 3 Lubricating controling a hoist cable The hoisting cable must be regularly greased or lubricated with Teflon For this use for exampl...

Page 13: ...ensor is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or cha...

Page 14: ...nd stopper ref 540620 Capacitor 40uF ref 540582 Pendant control ref 461020 Motor cap ref 540601 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the curren...

Page 15: ...INSTRUCTION MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 15 17 Version 23 21...

Page 16: ...ntensity of use 4 2 1 Model ref 461025 This model follows the recommendations of EN60204 32 2008 It contains a transmitter IP65 and a receiver with internal antenna IP66 range 75 to 100m Frequency ban...

Page 17: ...6 Page 17 17 Version 23 21 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33...