background image

 

INSTRUCTION MANUAL 

Electrical winches LM90A/LM250A

 

Réf : 1813000156 
Page : 

4/17

 

Version : 23/21 

A test prior to initial commissioning and after each 
maintenance or dismantle must be performed with a 
static  test  coefficient  of  1.25xWLL  and  a  dynamic 
test coefficient of 1.1xWLL. 

1.4

 

Specifications  

The  LM  winch  has  a  working  load  limit  (WLL) 
displayed on the winch plate. 

Type 

LM250A 

LM90A 

LM90B 

CMU / WLL (kg) 

250 

90 

Motor P (kW) 

0.45 

Voltage (V) 

230V-50Hz 

230V 60Hz 

I Nominal / start (A) 

3.5/11A 

4.6/12A 

Weight (kg) 

21 

Dimensions (mm) 

219x260x503 

T° for use (° C) 

-10°C / +55°C *

Operating Speed (m/s) 

0.1 (6m/mn) 

0.28 (17m/mn) 

0.33 (20m/mn) 

Wire rope Ø and type 

Ø5 galvanized steel 

Minimum breaking load (kg) 

1800 

Upper limit switch 

Yes 

Lower limit switch 

Yes 

Service factor 

S3 50% 30cy/h 

*

Use  between  -20°  and  -10°C  is  possible

providing  a  gradual  and  uniform  preheating
unloaded operation is carried out, then the load can
be applied as soon as the hoist reaches a T ° - 10°C.

1.5

 

Machine logbook, 

The contents of the logbook of this machine are not 
provided;  it  is  up to  the owner  to  create  or  acquire 
one in which the following is noted: 
-

the  name  of  the  person  in  charge  of

equipment
-

operator names and dates / periods of use

-

serial numbers of components

-

the number of hours of use,

-

the characteristics of the cables used

-

the number of hours the cables are used,

-

a  record  of  incidents  and  actions  taken  to

remedy them
-

forecast  dates  of  periodic  inspections  and

record of actual dates of inspections

1.6

 

Recommendations for use and general 
safety 

Before using this equipment, ensure: 

- that  you  read  and  understand  this  entire

manual

- that  no  obstacles  will  obstruct  the  required

motion

- that  the  periodic  inspection  has  been

performed and recorded,

- that  the  electrical  installation  is  designed  and

protected according to current regulations

- that your material is stable and aligned, freely

with the load

- the  load  or  machine  movements  will  not  trap

or crush you or other people; signal and block
access to the area under the load

- you  can  communicate  with  help  in  case  of

need,

- that you have adequate lighting

ensure : 

- every  day  the  correct  operation  of  the

mechanisms, brakes, and emergency stop

- periodically  the  electrical  cables,  limit

switches, structural elements and wire ropes

- regularly  the  presence  of  travel  end  stopper,

the  presence  of  plates  and  safety  instructions
(and their readability),

- safety of the suspension structure
- there  is  no  accumulation  of  snow,  ice,  debris

or materials on the winch,

- that there are no obstructions on the façade or

in the shaft

- at  the  end  of  work,  that  the  deactivation  is

complete.

- If a charge is to be raised by multiple devices,

the installation of these must be preceded by a
technical  review  by  a  competent  technician
and  then  conducted  according  to  this  study,
including  to  ensure  the  constant  distribution
of the load in suitable conditions.

Summary of Contents for LM250A

Page 1: ...MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 1 17 Version 23 21 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 08th Jun 2021 New format type A for Radio option modif...

Page 2: ...ARNINGS ABOUT CONTRAINDICATIONS 10 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENANCE OPERATIONS 11 3 1 1 Preventive maintenance 11 3 1 2 Adjusting...

Page 3: ...r work such as in an elevator shaft or on building facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable...

Page 4: ...a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections 1 6 Recommendations for use and general safety Before using thi...

Page 5: ...r the effort to apply If the anchoring is not provided by FIXATOR each anchor must withstand without any deformation up to 2 5 times the WLL of the winch that is 2 5x90 225 kg respectively 2 5x250 625...

Page 6: ...ualified technician 2 1 1 Suspended installation It s the simplest mounting and the most common Device in suspension and direct traction or lifting The anchoring of the device must be done exclusively...

Page 7: ...ft height plus at least 1 meter of apparent slack strand The limit spring mounted on the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve...

Page 8: ...e main power plug 2 1 4 2 Commissioning Unlock the emergency stop if necessary Press the UP button to lift or pull the load Press the DOWN button to lower the load At any time in case of imminent dang...

Page 9: ...t the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installation and use...

Page 10: ...he load Avoid heavy slipping Wait for a complete stop of your installation before resuming movement Check regularly that no obstacle is located along the path of movement above and below the load 2 4...

Page 11: ...ust be reviewed at least once a year and every 100h In harsh environments sandblasting marine back and forth operation at full load doubts about the proper use etc a higher frequency of verifications...

Page 12: ...ly original FIXATOR parts ask the complete list of spare parts 3 1 3 Lubricating controling a hoist cable The hoisting cable must be regularly greased or lubricated with Teflon For this use for exampl...

Page 13: ...ensor is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or cha...

Page 14: ...nd stopper ref 540620 Capacitor 40uF ref 540582 Pendant control ref 461020 Motor cap ref 540601 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the curren...

Page 15: ...INSTRUCTION MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 15 17 Version 23 21...

Page 16: ...ntensity of use 4 2 1 Model ref 461025 This model follows the recommendations of EN60204 32 2008 It contains a transmitter IP65 and a receiver with internal antenna IP66 range 75 to 100m Frequency ban...

Page 17: ...6 Page 17 17 Version 23 21 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33...

Reviews: