background image

 

INSTRUCTION MANUAL 

Electrical winches LM90A/LM250A

 

Réf : 1813000156 
Page : 

8/17

 

Version : 23/21 

Stop  immediately  if  the  loose  strand  comes  to 
tangle with the other strands. 

2.1.4

 

Power 

The  installer  must  ensure  that  the  power  supply  is 
compatible with the specification of the winch. 

The  power  supply  must  be  protected 

upstream  by  a  30  mA  differential  switch.  The 
installation  must  be  in  accordance  with  EN  60204-
1. Power outlets must be calibrated to 10A.
The  power  cable  to  the  LM  control  box  must  be
flexible  cable  (Class  5).  Beyond  30m,  it  must  be
held in place by a suitable anchorage clamp.
EXTENSION SECTION (mm²) at 

230V

Type : 

0-50m

50-100m

100-180m

3 wires 
P+N+T 

1.5² 
15AWG 

2.5² 
13AWG 

4.0² 
11AWG 

If  the  LM  winch  is  powered  by  a  generator,  check 
that  it  delivers  at  least  the  voltage  and  power 
required at the start of the winch (min 3kVA). 

2.1.4.1

 

Hoist connection 

- Connect  the  button  box  to  the  socket  on  the

winch.

- Connect the main power plug.

2.1.4.2

 

Commissioning 

- Unlock  the  emergency  stop  if

necessary

- Press  the  UP  button  to  lift  or  pull  the

load

- Press  the  DOWN  button  to  lower  the

load

At any time, in case of imminent danger or 
need, press the Punch red button to stop any 
movement of your hoist. 

2.1.5

 

Installation of cables for lifting 

Use  protective  gloves  when  handling  wire 

rope. 
Check  the  condition  of  the  cable  and  its  length 
(working  2m).  
Check the condition of the hook and safety latch. 

Avoid the formation of loops when unwinding..

The end of the cable should be clean and sharp. 

pour votre sécurité, n’utiliser que des câbles 

FIXATOR 

Put  the  end  stopper  on  the  wire  rope  (the  spring 
being  directed  to  the  winch).  Block  with  an  Allen 
key. 

Insert  the  end  of  the  wire  rope  through  the  bottom 
opening  A.  press  the  UP  button  on  the  pendant 
control  while  pushing  the  wire  rope  so  that  it 
engages in the throat of the pulley. 
When  the  rope  come  out  through  hole  B,  continue 
the movement so as to obtain a sufficient length of 
wire rope. 

PS  :  a  second  stopper  is  provided  to  stop  the 
descent;  position  the  spring  on  the  side  of  the 
winch: 

Summary of Contents for LM250A

Page 1: ...MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 1 17 Version 23 21 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 08th Jun 2021 New format type A for Radio option modif...

Page 2: ...ARNINGS ABOUT CONTRAINDICATIONS 10 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENANCE OPERATIONS 11 3 1 1 Preventive maintenance 11 3 1 2 Adjusting...

Page 3: ...r work such as in an elevator shaft or on building facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable...

Page 4: ...a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections 1 6 Recommendations for use and general safety Before using thi...

Page 5: ...r the effort to apply If the anchoring is not provided by FIXATOR each anchor must withstand without any deformation up to 2 5 times the WLL of the winch that is 2 5x90 225 kg respectively 2 5x250 625...

Page 6: ...ualified technician 2 1 1 Suspended installation It s the simplest mounting and the most common Device in suspension and direct traction or lifting The anchoring of the device must be done exclusively...

Page 7: ...ft height plus at least 1 meter of apparent slack strand The limit spring mounted on the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve...

Page 8: ...e main power plug 2 1 4 2 Commissioning Unlock the emergency stop if necessary Press the UP button to lift or pull the load Press the DOWN button to lower the load At any time in case of imminent dang...

Page 9: ...t the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installation and use...

Page 10: ...he load Avoid heavy slipping Wait for a complete stop of your installation before resuming movement Check regularly that no obstacle is located along the path of movement above and below the load 2 4...

Page 11: ...ust be reviewed at least once a year and every 100h In harsh environments sandblasting marine back and forth operation at full load doubts about the proper use etc a higher frequency of verifications...

Page 12: ...ly original FIXATOR parts ask the complete list of spare parts 3 1 3 Lubricating controling a hoist cable The hoisting cable must be regularly greased or lubricated with Teflon For this use for exampl...

Page 13: ...ensor is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or cha...

Page 14: ...nd stopper ref 540620 Capacitor 40uF ref 540582 Pendant control ref 461020 Motor cap ref 540601 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the curren...

Page 15: ...INSTRUCTION MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 15 17 Version 23 21...

Page 16: ...ntensity of use 4 2 1 Model ref 461025 This model follows the recommendations of EN60204 32 2008 It contains a transmitter IP65 and a receiver with internal antenna IP66 range 75 to 100m Frequency ban...

Page 17: ...6 Page 17 17 Version 23 21 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33...

Reviews: