background image

                                         

 

INSTRUCTION MANUAL 

Electrical winches LM500+

 

Réf : 1813000204 
Page : 

1/16

 

Version : 44/16 

 

 

 

 

 

INSTALLATION – USE 

MAINTENANCE

 

 

Monitoring of updates 

Date 

Description 

03/11/2016 

Creation 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LM500+

Page 1: ...INSTRUCTION MANUAL Electrical winches LM500 R f 1813000204 Page 1 16 Version 44 16 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 03 11 2016 Creation...

Page 2: ...CONTROL STATION 10 2 4 NORMAL USE 10 2 5 DECOMMISSIONING 11 2 6 WARNINGS ABOUT CONTRAINDICATIONS 11 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENAN...

Page 3: ...facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable is tight under the effect of the load by two artic...

Page 4: ...tics of the cables used the number of hours the cables are used a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections...

Page 5: ...hoisting cable into the device before the anchoring operation 2 Installation and Use 2 1 Instructions for installation assembly commissioning and use training Installation and use operations must be...

Page 6: ...cial precautions The bearing surface on which the unit is placed must be flat and horizontal This surface must have a minimum 120mm orifice for the passage of the two strands of cable The device must...

Page 7: ...n the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve as low end stopper In case of reeving double the maximum load to be taken into acc...

Page 8: ...ime in case of imminent danger or need press the Punch red button to stop any movement of your hoist 2 1 6 Installation of cables for lifting Use protective gloves when handling wire rope Check the co...

Page 9: ...Ensure that the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installatio...

Page 10: ...very 45 minutes of work to avoid overheating 2 3 Description of the work or control station Up and down hoist movements are controlled from the pendant control Never stand under the load In case of a...

Page 11: ...containing bisulphite or MoS2 Molykote etc To apply a load on the loose strand of the hoist To use the wire rope as a means to sling the load 2 7 Residual risks The use of cable damaged or not suited...

Page 12: ...ssing the 8 pivot After each operation a load test must be performed FIXATOR or its dealers can train your staff for the maintenance of your winches For your safety and to benefit from the full guaran...

Page 13: ...or is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or change...

Page 14: ...opper ref 462030 Capacitor ref 540144 Pendant control ref 462020 Motor cap ref 462021 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the current regulati...

Page 15: ...INSTRUCTION MANUAL Electrical winches LM500 R f 1813000204 Page 15 16 Version 44 16...

Page 16: ...Page 16 16 Version 44 16 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33 0...