Fixturlaser GO Pro Manual 2
nd
edition
6.14
SOFTCHECK
Go to Softcheck for checking
soft foot conditions.
See chapter “Softcheck”.
TARGET VALUES
Go to Target Values for
entering target values.
See chapter “Target Values”.
MEASUREMENT METHOD
Tripoint™ method
In the Tripoint method, the alignment
condition can be calculated by taking
three points while rotating the shaft at
least 90°.
NOTE: The shafts should be coupled
during measurement in order to achieve
as reliable and accurate results as
possible, when using the Tripoint
method.
TIP: The larger the angle over which the
three points are measured, the fewer
moves and repeat measurements will
have to be made. Minimum angle
between readings is 45°.
A green flashing arrow
suggests suitable
measurement positions.
Summary of Contents for GO Pro
Page 1: ...MANUAL Fixturlaser GO Pro user s...
Page 2: ......
Page 4: ...Fixturlaser GO Pro Manual 2nd edition September 2011...
Page 12: ...Fixturlaser GO Pro Manual 2nd edition 3 4...
Page 52: ...Fixturlaser GO Pro Manual 2nd edition 7 12...
Page 64: ...Fixturlaser GO Pro Manual 2nd edition 10 6...
Page 86: ...Fixturlaser GO Pro Manual 2nd edition 14 8...
Page 91: ......