Fixturlaser GO Pro Manual 2
nd
edition
7.6
ENTER DIMENSIONS
The screen displays the movable
machine.
Select the dimension
boxes to enter dimensions.
Measure and enter dimensions.
You must enter all the distances. The
distance between the sensors, the
distance between the centre of the
coupling and the M-sensor, and the
pitch circle diameter and the number of
bolts.
Up to 8 bolts can be entered.
MEASUREMENT METHOD
In the Vertical Shaft Alignment
program, machinery positions are
calculated by taking three points with
180° of rotation.