10
TARGET VALUES
INTRODUCTION
Most machines develop a certain
amount of heat while running. In the
best case both the driving and the
driven machine are affected equally
requiring no input of compensation
values. But in some applications the
driven machine is either hotter, i.e. a
pump for hot liquid, or cooler than the
driving machine.
Machine manufacturers define the
thermal expansion of machines
differently, but in most cases you will
find it as a factor of deliberate
misalignment expressed in parallel
offset and angular error.
In the Fixturlaser GO Pro system, you
can enter target values while doing your
alignment work. Accepted values are
feet values and angle and offset values.
The entered values are target values.
Target values mean that these are the
values at which the machine should be
positioned when not running (cold
condition) in order to obtain correct
alignment while the machine is running
(hot condition).