Fixturlaser GO Pro Manual 2
nd
edition
10.4
ANGLE AND OFFSET VALUES
Select the value boxes and enter target
values for the angles in mm/100 mm
and target values for the offsets in mm,
or mils/inch and mils, according to the
pre-set measurement unit.
In the example above, the movable
machine should be vertically adjusted to
a position with an angular misalignment
of +0.05 mm/100 mm and an offset of
-0.06 mm.
Horizontally, the movable machine
should be positioned with a
+0.02 mm/100 mm angular
misalignment and a +0.03 mm offset, in
cold condition to obtain perfect
alignment while running.