background image

Fixturlaser NXA Pro

M E A S U R E

Enter Dimensions

1. 

Touch the tape measure icon on the 

moveable machine image  

2.

 

Measure the indicated dimension to the nearest 1 mm 

for coupling dimensions or 2 mm for foot dimensions  
enter using the keypad.  Then press the check mark to 
move to the next dimension. Continue and enter all 
dimensions.

3.

 Select the RPM of the equipment to set the alignment 

tolerances, then press the check mark.

 

Measure Misalignment

The two preferred measurement methods:              

1. 

Select a measurement method by touching 

to go to the toolbox.

2. 

Touch the measurement icon on the stationary machine. 

The measurement mode screen will open. Select the 
Tripoint method and touch the check mark.

3. 

Touch the check mark again to return to the alignment 

measurement screen.

Tripoint (used in this example)

Express

Summary of Contents for NXA Pro

Page 1: ...Fixturlaser NXA pro Quick tips...

Page 2: ...ou and adjust the movable shaft to within 0 5 mm of the stationary hub 2 Correct Obvious Soft Foot Loosen all the bolts and find any obviously loose shim packs Add shims as needed to make a snug fit 3...

Page 3: ...e a Final Soft Foot Correction Loosen one bolt at a time and check for soft foot with a 0 05 mm shim or feeler gauge Correct any foot with 0 05 mm or more of soft foot then tighten the bolt before pro...

Page 4: ...nt Program 1 From the main menu on the display unit touch the horizontal alignment icon 2 The lasers will turn on and the screen graphic will show the orientation of the sensors Aim the Lasers 1 Loose...

Page 5: ...nue and enter all dimensions 3 Select the RPM of the equipment to set the alignment tolerances then press the check mark Measure Misalignment The two preferred measurement methods 1 Select a measureme...

Page 6: ...the flashing measurement button 5 Rotate the sensors to the 12 00 position being sure they move outside the red portion of the circle on the screen Press the measurement button again to take the seco...

Page 7: ...displayed on screen Evaluating the Results 1 Vertical results are displayed at the top of the screen horizontal results at the bottom 2 Green coupling icons indicate values which are in tolerance 3 O...

Page 8: ...tion pop up screen 2 Loosen all the bolts on the movable machine 3 Follow screen instructions for removing or inserting shims Do not re tighten the bolts Next Correct the Horizontal Misalignment 1 Fir...

Page 9: ...adjustment first The arrows indicate the direction of adjustment 5 Continue to adjust the movable machine watching the live readings until both the angle and offset are within tolerance 6 Tighten the...

Page 10: ...within tolerance If they are not repeat the Verti ZontalTM Correction Process top of page 7 Document the Results 1 Press the file save icon 2 Press the white file name box to open the keypad Enter a...

Page 11: ...have reached where we are today by having the courage to think beyond the norm and follow slightly unconventional paths We have had the courage to make mistakes and find new directions Through our re...

Page 12: ...www fixturlaser com ACOEM AB sterg rdsgatan 9 SE 431 53 M lndal SWEDEN Phone 4631 706 28 00 Fax 4631 706 28 50 P 0261 Quick tips Fixturlaser NXA Pro rev A...