START UP INSTRUCTIONS:
1.
Be sure the switch is in the “OFF” position.
2.
Ensure electrical cord is grounded and heater is on a level surface.
3.
Plug in supply cord to 115v, 15amp outlet.
4.
Move switch to “MANUAL” position for manual control.
5.
Move switch to “THERMOSTAT” position for thermostatic control.
Please Note:
1. If using Thermostat on unit, unit must be started in Thermostat position.
2. When changing between manual and thermostat operation, the heater
must be left in the “OFF” position for 30 seconds to prevent the burner
from locking out.
3. When using a generator for electrical supply, make sure the generator is
properly grounded and generator is at a 60Hz frequency.
4. In the event that a generator is being used and the generator runs out of
fuel, make sure the heater switch is in the “OFF” position before restarting
generator, failure to do so may damage heater.
TO SHUT DOWN:
1.
Close main gas supply valve while heater is operating.
2.
Move switch to “OFF” position.
3.
Disconnect heater from gas supply.
NOTE:
Fan will continue to operate after the burner shuts down. Once the
unit cools down, the fan will stop.