- 10 -
IF HEATER FAILS TO START:
1.
Press manual reset button at rear of burner.
2.
Check gas pressure supply. Supply and manifold pressure must
follow those on rating plate.
3.
Ensure proper power supply is being used.
4.
If heater fails to ignite after 3 attempts, call your supplier for service.
SAFE OPERATION PRECAUTIONS:
1.
For use with propane or natural gas only. Fuel sector valve must be in
correct position. See approval label.
2.
Use Thermostat/Manual switch to shut down the heater. Do not try to
shut down the heater by the disconnect switches or unplugging the
electrical cord.
3.
Do not plug anything other than the thermostat into the “Thermostat”
plug.
4.
Follow electrical requirements shown on rating plate and/or Electrical
requirements section of this manual.
5.
Before removing any guards or performing any maintenance, be sure
that the main power supply is disconnected.
6.
The hose assembly shall be protected from traffic, building material &
contact with hot surfaces, both during use & while in storage
Summary of Contents for FVN-750