INSTALLATION:
The installation of this heater for use with natural gas shall conform with local
codes or, in the absence of codes, with the National Fuel Gas Code ANSI
Z233.1/NFPA 54 and the Natural Gas and Propane Installation Code, CSA
B149.1. This heater must be installed by a qualified gas technician, following
local codes published by the authority having jurisdiction. All installations
performed in the state of Massachusetts must be completed by a qualified
plumber and gas fitter of the State of Massachusetts.
The installation of this heater for use with propane tank or cylinder shall conform
with Local codes or, in the absence of local codes, with the Standard for the
Storage and Handling of Liquefied Petroleum Gases, ANSI / NFPA 58 and the
Natural Gas and Propane Installation Code, CSA B149.1.
This heater must be located at least 10ft (3m) from any propane gas cylinder.
This heater shall not be directed toward any propane gas container within 20ft
(6m).
CLEARANCE TO COMBUSTIBLES:
TOP
FRONT
SIDES
REAR
FLUE PIPE
1 ft
1 ft
1 ft
2 ft
2 ft
CONNECTING THE CYLINDER (LP Models only):
The heater must be located at least 6ft (1.83m) in the U.S.; or 10ft (3m) in
Canada, from any propane gas container
If cylinders are used to supply the heater, no cylinders smaller than 100lb
capacity shall be used. These cylinders must supply a vapor withdrawal only.
1.
All cylinder connections must be made using a wrench to tighten the POL
fitting.
2.
Be sure that the cylinder valve is in the closed position when connection or
disconnecting the cylinder.
3.
A soap and water solution must be applied to all connections in order to
leak check the system.