5.2 The compressor does not reach the

maximum pressure

·

a) Check any air leak (See point 5.6).

·

b) Check the pressure switch efficency and
if necessary adjust it (See page 10
Pressure adjustment).

·

c)The non-return-valve is clogged so crea-
ting a flow restriction.
Clean or replace the valve.

5.3 The compressor works, but pressure

does not increase in tank
(or increase too slowly)

·

a) The transportation cap has not been re-
moved from the air intake pipe (or hole).

·

b) Air filter clogged. Clean or replace.

·

c) Check any air leak (See point 6).

5.4 The compressor works but does not load

·

The defect can be due to a valve or a ga-
sket break (Fig.11). Replace the damaged
part immediately.

5.5 The compressor stops while working

·

The motor has an automatic resetting ther-
mal protection, that stops the compressor
when the temperature is too high. The
compressor will start again automatically
after 15/20 minutes.

5.6 Air leaks

·

Can be due to bad seal of any connection,
check all connections wetting with suds.

5.2 Kompressoren når ikke op på maks tryk

·

Det kontrolleres, om der er utætheder (se
punkt 5.6).

·

b) Check the pressure switch efficency and
if necessary adjust it (See page 10
Pressure adjustment).

·

c) En fejl i kontraventilen forhindrer
strømning. Ventilen udskiftes.

5.3 Kompressoren fungerer, men trykket i
tanken stiger ikke (eller stiger for langsomt)

·

A) Transporthætten er ikke blevet fjernet
fra luftindtagsledningen (eller hullet).

·

b) Luftfilteret er tilstoppet. Filteret rengøres
eller udskiftes.

·

c) Det kontrolleres, om der er utætheder
(se punkt 6).

5.4 Kompressoren kører, men trykket

stiger ikke

·

Fejlen kan skyldes brud på ventil eller
pakning (fig. 11). Den defekte del udskiftes
straks.

5.5 Kompressoren stopper under drift

·

Motoren har en automatisk varmesikring,
der stopper kompressoren, når
temperaturen bliver for høj. Kompressoren
starter automatisk igen efter 15-20
minutter.

5.6 Utætheder

·

Kan skyldes dårlig tætning af forbindelse.
Alle forbindelser kontrolleres ved hjælp af
sæbevand.

17

Summary of Contents for FLAIR 4 AIR S33.15

Page 1: ...RMO Baldersgade 12 DK 90000 Aalborg www FLAIRMO com S N YEAR Rev 0 29 12 09 Authorized service center AUTOMATIC SILENT COMPRESSORS AUTOMATISKE STØJSVAGE KOMPRESSORER S33 4 S33 15 S33 24 S66 24 S66 50 S99 50 ...

Page 2: ...al informations 19 6 1 Compressor demolition 19 6 2 Spares 19 6 3 Warranty 19 Indhold 1 Generel information 3 1 1 Betydning og anvendelse af den manuelle 3 1 2 Indhold 3 1 3 Opbevaring 3 1 4 Vægt og dimensioner 3 1 5 Pakning bortskaffelse 4 1 6 Løft og håndtering 4 1 7 Sikkerhed 4 1 8 Hovedkomponenter 5 2 Tekniske data 6 2 1 Tekniske data 6 2 2 Kurver for luftindtag tryk 6 2 3 Ledningsdiagrammer 7...

Page 3: ...formation 1 1 Betydning og anvendenelse af den manuelle Denne vejledning udgør en integreret del af kompressoren og skal altid ledsage denne også i tilfælde af salg Ejeren af kompresso ren og eller brugeren skal have gennemlæst nærværende betjeningsvejledning og anbe falinger grundigt før kompressoren tages i brug Hvis operatøren ikke fuldt ud forstår det sprog der anvendes i vejledningen skal for...

Page 4: ...y cause serious damage to the compres sor and or to the persons 1 5 Pakning bortskaffelse Når kompressoren er taget ud af pakningen kontrolleres det at der ikke er nogen dele der er blevet beskadiget under transporten Indpakningsmaterialet skal bortskaffes i henhold til de regler der gælder i det land hvor kompressoren opstilles Materialet kan også genbruges 1 6 Løft og håndtering Kompressorerne s...

Page 5: ...itch 4 Tank pressure gauge 5 Filter reducer 6 Outlet pressure gauge 7 Safety valve 1 8 Hovedkomponenter 1 Motor 2 Lufttank 3 Pressostat 4 Tankmanometer 5 Trykluftfilter og regulator 6 Manometer til måling af udgangstryk 7 Sikkerhedsventil 5 3 1 7 2 4 5 6 ...

Page 6: ... Gal dB A 1m dB A 40 S33 4 230 50 0 34 2 40 50 8 3 5 45 115 60 0 40 4 80 2 10 116 0 93 45 S33 15 230 50 0 34 2 40 50 8 15 45 115 60 0 40 4 80 2 10 116 3 96 45 S33 24 230 50 0 34 2 40 50 8 24 45 115 60 0 40 4 80 2 10 116 6 34 45 S66 24 230 50 0 68 4 80 100 8 24 47 115 60 0 80 9 60 4 20 116 6 34 47 S66 50 230 50 0 68 4 80 100 8 50 47 115 60 0 80 9 60 4 20 116 13 47 S99 50 230 50 1 02 7 20 150 8 50 4...

Page 7: ...E Yellow Green 4 Pressure switch A Black 5 Capacitor B White D Brown F Sky blue G Yellow Green 2 3 Ledningsdiagrammer 1 Startrelæ L Brun 2 Overbelastningssikring N Blå 3 Klemkasse E Gul grøn 4 Pressostat A Sort 5 Kondensator B Hvid D Brun F Sky blue G Gul grøn 7 MOTOR TYPE 33 MOTOR TYPE 33 ...

Page 8: ...through the oil level glass OIL MUST NEVER BE OVER THE MAX OIL LEVEL Fig 1 3 Operation 3 1 Opsætning af maskine Kompressoren placeres på jævnt underlag i et lokale der er tilstrækkeligt stort ventileret og ikke fugtigt og hvor temperaturen ikke stiger til over 35ºC Hvis der ikke er tilstrækkelig ventilation installeres udsugningsventilator eller blæser med tilstrækkelig kapacitet I Advarsel KOMPRE...

Page 9: ...o position 1 The compressor working process is automatic Fig 2 DER MÅ ALDRIG ANVENDES ANDEN OLIE END DEN DER ANBEFALES AF PRODUCENTEN HVIS DER ANVENDES ANDEN OLIE BORTFALDER ALLE GARANTIER Hvis der er olie tilovers opbevares dette til senere påfyldning Indtagsfilteret genmonteres på ledningen eller i hullet ved let tryk med hånden Når der er blevet påfyldt olie må kompres soren ikke væltes eller t...

Page 10: ... C Rotate the screw C clockwise to reduce differential pressure I Attention Pressure regolation must be carried out by skilled personnel only Pressostaten stopper kompressoren når trykket i tanken når den tilladte maksimumværdi 8 bar 116psi stan dard og starter den igen når trykket falder til minimumsværdien 6 bar 87psi standard Udgangstrykket justeres ved hjælp af knappen på trykluftregulatoren T...

Page 11: ...r type 66 1 5 mm22 2 5 mm2 1 5 mm22 2 5 mm2 Motor type 99 1 5 mm22 2 5 mm22 2 5 mm22 2 5 mm22 Hvis pressostaten ikke virker overtryk aktiveres sikkerhedsventilen automatisk og åbnes når trykket overstiger den indstillede maksimumværdi I Advarsel Kompressorerne skal tilsluttes en ud gang der er beskyttet af en magneto ter misk kontakt Tabellerne viser ampereforbrug for hver enkelt kompressortype Mo...

Page 12: ...urves represent average values at 230V 50Hz operation with an outside tempera ture 20 C Fig 5 3 3 Begrænsninger for kontinuerlig drift Kurve nr 1 angiver varigheden af kontinu erlig drift ved forskelligt tryk indtil overbe lastningssikringen standser motoren ved en olietemperatur på ca 115ºC målt med et udgangspunkt på 20ºC Eksempel 6 bar 116 minutter Kurve nr 2 angiver det anbefalede forhold mel ...

Page 13: ...l af fyldningstid Udføre følgende handlinger 1 Tøm kompressor luft tank 2 Luk kompressoren forretningen på tanken og kontrollér at afløbet cap er lukket 3 Start kompressoren og kontrollere den tid der går mellem start og automatisk slukning 4 Kontroller at der ikke er utætheder om forbindelser 5 check max tryk 8 bar 116 Psi 13 Filling up time of the tank from 0 to max pressure in seconds Fyldnings...

Page 14: ...tap Fig 7 En gang fjernes det kondensat der har samlet sig i lufttanken For at tømme tanken sættes den under tryk og kompressoren flyttes til et sted hvor vandet ikke vil beskadige gulvet Kompressoren vippes forsigtigt forover og hanen på tankens underside åbnes fig 5 Once a month check the compressor efficiency possible connectors slackening pressure hose wear screws tightening electric circuit e...

Page 15: ...ause severe mechani cal damages to the compressor Consequently warranty is valid only if the proper oil is used 4 2 Oliesubstitution Fungere som følger fig 10 1 fjerne motoren enhed fra tanken hvis det er nødvendigt 2 fjerne finned dække af at miste de 4 skru er 3 vippe motor enhed mod afgangssiden ikke vende op og ned og samtidig holde den indre enhed i dens sæde med din hånd 4 Tøm alle olie Bemæ...

Page 16: ...ically turn on at the suitable temperature 5 Fejlfinding I Advarsel Stikket skal fjernes fra stikkontakten før der foretages indgreb på kompressoren Lufttanken tømmes for luft før der demon teres dele fra kompressorens tryksystem De følgende indgreb må kun foretages af faglærte teknikere 5 1 Kompressoren starter ikke A Der kommer ingen strøm fra strømfor syningsnettet Sikringer og stikkontakt kon ...

Page 17: ...inutes 5 6 Air leaks Can be due to bad seal of any connection check all connections wetting with suds 5 2 Kompressoren når ikke op på maks tryk Det kontrolleres om der er utætheder se punkt 5 6 b Check the pressure switch efficency and if necessary adjust it See page 10 Pressure adjustment c En fejl i kontraventilen forhindrer strømning Ventilen udskiftes 5 3 Kompressoren fungerer men trykket i ta...

Page 18: ...s the correct mo del for your work load 5 7 Utæthed ved ventil placeret under pressostat a Defekt ventil Ventil udskiftes b Defekt kan også skyldes dårlig ventiltætning se punkt 5 1d 5 8 Kompressoren starter når der ikke tappes luft Utæthed se punkt 5 6 5 9 Kompressoren starter og stopper oftere end normalt a Stor mængde kondensat i lufttanken Kondensat fjernes b Utæthed se punkt 5 6 5 10 Kompress...

Page 19: ... worn parts The guarantee automatically ceases in case of tampering and bad usage The warranty does not include transport and labour costs 6 Specielle oplysninger 6 1 Nedtagning af kompressor Ved nedtagning af kompressor skal alle sikkerhedsregler iagttages for at forhin dre personog tingsskade Alle metaldele kan genbruges Gummi og plastdele skal bortskaffes i henhold til gæl dende lov i det land ...

Reviews: