background image

Cooker hood CPD - Technical manual

5

FläktGroup 

DC-8757GB 20180426_R1

Specifications are subject to alteration without notice

NORMAL

MIN

MAX

MIN

1

2

MIN

1

2

MIN

1

2

MAINTENANCE

OPERATING OF CPDB, CPDC, CPDG, CPDH AND CPDK

Handle for boosting

Lighting

Handle for fan speed

MIN

1

2

FG_DC_8757GB_CPD_IN-MA-SP_20180426_R1.indd   5

2018-04-26   16:06

Summary of Contents for CPDA

Page 1: ...TECHNICAL MANUAL COOKER HOOD CPD FG_DC_8757GB_CPD_IN MA SP_20180426_R1 indd 1 2018 04 26 16 06...

Page 2: ...R THE USER Cleaning 3 Replacing of the low energy lamp 3 General 3 Operating of CPDA and CPDJ 4 Operating of CPDB CPDC CPDG CPDH CPDK 5 INSTALLATION FOR INSTALLERS AND SERVICE PERSONNEL Installation h...

Page 3: ...week Clean if needed Note Do not use the cooker hood without grease filter fitted GENERAL There is a fire risk if cleaning is not carried out in accordance with the instructions Accessible parts may...

Page 4: ...anual 4 Fl ktGroup DC 8757GB 20180426_R1 Specifications are subject to alteration without notice MAINTENANCE OPERATING OF CPDA AND CPDJ Handle for boosting Lighting FG_DC_8757GB_CPD_IN MA SP_20180426_...

Page 5: ...Specifications are subject to alteration without notice NORMAL MIN MAX MIN 1 2 MIN 1 2 MIN 1 2 MAINTENANCE OPERATING OF CPDB CPDC CPDG CPDH AND CPDK Handle for boosting Lighting Handle for fan speed M...

Page 6: ...qualified persons in order to avoid hazard The distance between the stove and the lower edge of the cooker hood has to be at least 400 mm recommended distance 500 mm When the cooker hood is located ab...

Page 7: ...600 a 500 200 100 100 415 365 365 255 205 205 INSTALLATION FOR INSTALLERS AND SERVICE PERSONNEL CPDA Intended for multiple unit dwellings with a central extract air fan or a heat recovery unit Suitabl...

Page 8: ...D aa with capacitor box manufactured before 2007 JBDD aa earlier version CPCB JBDD aa earlier version a a b b CPDC Replacement hood for older heat recovery unit RDKG without bypass fits RDKG a 1 c d 1...

Page 9: ...for example JBDB JBDC and RDAA INSTALLATION FOR INSTALLERS AND SERVICE PERSONNEL 3 2 1 RDKS 4 5 4 1 4 2 2 3 1 JBDD 1 2 1 Orange Supply voltage to fan 2 Blue Neutral 3 Black Phase 4 Yellow Green Groun...

Page 10: ...t notice CPDH Replacement hood for older heat recovery units RDKG with bypass Fits RDKG a 2 c d 1 a b CPDK For heat recovery unit RDKG Fits RDKG a b c d 2 a b INSTALLATION FOR INSTALLERS AND SERVICE P...

Page 11: ...ce INSTALLATION FOR INSTALLERS AND SERVICE PERSONNEL CPDJ For heat recovery unit RDKR or RDKS a b 3 2 1 RDKS RDKS 4 5 4 1 4 2 7 6 It is important to seal the grommet by putting back the small piece of...

Page 12: ...version kit JBDB 99 05 0 JBDB1 CPDG CPTG Supply 230V JBDA 99 031 2 F not included N L Blue Blue White Black Black Yellow Green Yellow Green Orange JBFG CPDG CPTG Supply 230V N L Blue Blue Brown Black...

Page 13: ...ect to alteration without notice ADJUSTMENT b c a Pa a 7 5 10 12 5 15 20 25 250 200 100 50 40 30 5 6 7 8 9 10 12 15 20 30 Air flow q l s Measuring pressure p m Pa 30 30 1xC 30 4xC 30 2xC CPDA CPDB CPD...

Page 14: ...CPDG FORCED VENTILATION When adjusting the forced air flow the fan speed must be increased up to the forced flow 10 20 30 40 50 100 200 150 20 30 40 50 80 Air flow q l s Measuring pressure p m Pa b 5...

Page 15: ...plate 1 2 3 4 5 6 7 8 9 10 p 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 10 8 6 4 2 Air flow q l s Measuring pressure p m Pa 2 4 6 8 och 10 numb...

Page 16: ...ED VENTILATION Damper blade without basic flow valve sealed damper blade When adjusting the forced air flow the fan speed must be increased up to the forced flow ADJUSTMENT 10 20 30 40 50 100 200 150...

Page 17: ...5 1 CPDA 99 10 Timer with shaft 500 mm M 600 mm M 700 mm M L x x x 5 1 CPDJ 99 01 Timer w shaft 600 700 mm w contact function x 6 10 CPCA 99 09 Lamp socket x x x x x x x 6 10 CPDA 99 12 Lamp socket tr...

Page 18: ...ectrical appliances Safety Part 1 General requirements EN 60335 2 31 Household and similar electrical appliances Safety Part 2 Particular requirements EN 61000 6 1 Electromagnetic compatibility EMC Pa...

Page 19: ...t it is may not all parts components materials be rep resented Printed circuit boards cables batteries motors sensors etc Filters except made of pure metal in cooker hoods Packaging materials such as...

Page 20: ...novative technologies high quality and outstanding performance supported by more than a century of accumulated industry experience The widest product range in the market and strong market presence in...

Reviews: