Heat recovery unit RDKS - Technical manual
14
FläktGroup DC_9295GB_20190326_R5
We reserve the right to make changes without prior notice
WIRING AND CONNECTION DIAGRAM
WIRING AND CONNECTION DIAGRAM, CONTROL CARD
230 V
L
N
PE
Max 24V, 200 mA
Timer 1
Timer 2
USB
N
M
DI
M
DI
L
C
NO
N
L
N
L
N
L
Tacho
1 N
2 L
3 N
4 L
5 N
27
70 69 68
67 66 65 64
28
37
32
33
34
38
35
36
13
14
15
16
51 50
49 48
47 46
6 L
7 N
8 L
11 N
12 L
0 V
+10 V
A
A
B
B
B
A
GND
Output 0-10V
+24 V
GND
N
L
0 V
+10 V
N L
board
Door switch
Sum alarm
Impeller
Extract air fan
CO
2
sensor
External alarm (Volt free contact)
Supply air fan
Temp. outdoor
Temp. extract
Moisture sensor extract air
Moisture sensor supply air
Temp. supply
Post-heater
Pre-heater
Ethernet board (accessory)
RS485
ISYteq Touch
ISYteq Basic
Cooker hood